get_building_typology
path: inputs/building-properties/typology.dbf
The following file is used by these scripts: archetypes_mapper
, demand
, emissions
Variable |
Description |
---|---|
|
First (Main) Use type of the building |
|
Fraction of gross floor area for first Use Type |
|
Second Use type of the building |
|
Fraction of gross floor area for second Use Type |
|
Third Use type of the building |
|
Fraction of gross floor area for third Use Type |
|
Unique building ID. It must start with a letter. |
|
Reference to data (if any) |
|
Construction Standard (relates to “code” in Supply Assemblies) |
|
Construction year |
get_costs_operation_file
path: outputs/data/costs/operation_costs.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Occupied floor area (heated/cooled) |
|
Annualized capital expenditures of building-scale systems |
|
Annualized capital expenditures of district-scale systems |
|
Operation costs of coal due to space heating per unit conditioned floor area |
|
Operation costs of coal due to space heating |
|
Operation costs of coal due to hotwater per unit conditioned floor area |
|
Operation costs of coal due to hotwater |
|
Operation costs of district cooling due to data center cooling per unit conditioned floor area |
|
Operation costs of district cooling due to data center cooling |
|
Operation costs of district cooling due to cool room refrigeration per unit conditioned floor area |
|
Operation costs of district cooling due to cool room refrigeration |
|
Operation costs of district cooling due to space cooling per unit conditioned floor area |
|
Operation costs of district cooling due to space cooling |
|
Operation costs of district heating due to space heating per unit conditioned floor area |
|
Operation costs of district heating due to space heating |
|
Operation costs of district heating due to domestic hot water per unit conditioned floor area |
|
Operation costs of district heating due to domestic hot water |
|
Operation costs due to electricity supply from the grid per unit conditioned floor area |
|
Operation costs due to electricity supply from the grid |
|
Unique building ID. It must start with a letter. |
|
Operation costs of natural gas due to space heating per unit conditioned floor area |
|
Operation costs of natural gas due to space heating |
|
Operation costs of natural gas due to domestic hot water per unit conditioned floor area |
|
Operation costs of natural gas due to domestic hot water |
|
Operation costs of oil due to space heating per unit conditioned floor area |
|
Operation costs of oil due to space heating |
|
Operation costs of oil due to domestic hot water per unit conditioned floor area |
|
Operation costs of oil due to domestic hot water |
|
Annual operational expenditures of building-scale systems |
|
Annual operational expenditures of district-scale systems |
|
Operation costs due to electricity supply from PV per unit conditioned floor area |
|
Operation costs due to electricity supply from PV |
|
Operation costs due to solar collectors for space heating per unit conditioned floor area |
|
Operation costs due to solar collectors for space heating |
|
Operation costs due to solar collectors for domestic hot water per unit conditioned floor area |
|
Operation costs due to solar collectors for domestic hot water |
|
Operation costs of wood due to space heating per unit conditioned floor area |
|
Operation costs of wood due to space heating |
|
Operation costs of wood due to domestic hot water per unit conditioned floor area |
|
Operation costs of wood due to domestic hot water |
get_demand_results_file
path: outputs/data/demand/B001.csv
The following file is used by these scripts: decentralized
, optimization
, sewage_potential
, thermal_network
Variable |
Description |
---|---|
|
Coal requirement for space heating supply |
|
Coal requirement for hotwater supply |
|
Time stamp for each day of the year ascending in hour intervals. |
|
District cooling for data center cooling demand |
|
District cooling for refrigeration demand |
|
Energy consumption of space cooling system (if supplied by District Cooling), DC_cs = Qcs_sys / eff_cs |
|
Energy requirement by district heating (space heating supply) |
|
Energy requirement by district heating (hotwater supply) |
|
Data centre cooling specific electricity consumption. |
|
Refrigeration system electricity consumption. |
|
Energy consumption of cooling system (if supplied by electricity grid), E_cs = Qcs_sys / eff_cs |
|
Heating system electricity consumption. |
|
End-use total electricity consumption = Ea + El + Edata + Epro + Eaux + Ev + Eve |
|
Hot water system electricity consumption. |
|
End-use electricity for appliances |
|
End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W |
|
End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux |
|
End-use data centre electricity consumption. |
|
End-use electricity for lights |
|
End-use electricity consumption for industrial processes. |
|
End-use electricity for electric vehicles |
|
End-use electricity for ventilation |
|
Grid electricity consumption for appliances |
|
Grid electricity consumption for auxiliary loads |
|
Grid electricity consumption for servers cooling |
|
Grid electricity consumption for refrigeration |
|
Grid electricity consumption for space cooling |
|
Grid electricity consumption for servers |
|
Grid electricity consumption for space heating |
|
Grid total electricity consumption, GRID_a + GRID_l + GRID_v + GRID_ve + GRID_data + GRID_pro + GRID_aux + GRID_ww + GRID_cs + GRID_hs + GRID_cdata + GRID_cre |
|
Grid electricity consumption for lighting |
|
Grid electricity consumption for industrial processes |
|
Grid electricity consumption for ventilation |
|
Grid electricity consumption for hot water supply |
|
Radiative heat loss |
|
Net radiative heat gain |
|
Solar heat gain |
|
Capacity flow rate (mass flow* specific heat capacity) of the chilled water delivered to data centre. |
|
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to refrigeration. |
|
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to air handling units (space cooling). |
|
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to air recirculation units (space cooling). |
|
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to space cooling. |
|
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to sensible cooling units (space cooling). |
|
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to air handling units (space heating). |
|
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to air recirculation units (space heating). |
|
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to space heating. |
|
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to sensible heating units (space heating). |
|
Capacity flow rate (mass flow* specific heat capacity) of the fresh water |
|
Capacity flow rate (mass flow* specific heat capacity) of domestic hot water |
|
Unique building ID. It must start with a letter. |
|
NG requirement for space heating supply |
|
NG requirement for hotwater supply |
|
OIL requirement for space heating supply |
|
OIL requirement for hotwater supply |
|
Predicted occupancy: number of people in building |
|
PV electricity consumption |
|
Latent heat gain from people |
|
Sensible heat gain from appliances |
|
Sensible heat gain from transmission through the base |
|
Sensible heat gain from data centres |
|
Sensible heat gain from lighting |
|
Sensible heat gain from people |
|
Sensible heat gain from industrial processes. |
|
Sensible heat gain from transmission through the roof |
|
Sensible heat gain from ventilation and infiltration |
|
Sensible heat gain from transmission through the walls |
|
Sensible heat gain from transmission through the windows |
|
Sensible heat loss from refrigeration systems |
|
Total energy demand for cooling, QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys |
|
Data centre space cooling demand |
|
End-use data center cooling demand |
|
Process cooling demand |
|
Refrigeration space cooling demand |
|
End-use refrigeration demand |
|
Cooling system distribution losses |
|
Cooling system emission losses |
|
Specific cooling demand |
|
AHU latent cooling demand |
|
ARU latent cooling demand |
|
Total latent cooling demand for all systems |
|
AHU sensible cooling demand |
|
ARU sensible cooling demand |
|
SHU sensible cooling demand |
|
Total sensible cooling demand for all systems |
|
AHU system cooling demand |
|
ARU system cooling demand |
|
End-use space cooling demand, Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls |
|
SCU system cooling demand |
|
Total energy demand for heating, QH_sys = Qww_sys + Qhs_sys + Qhpro_sys |
|
Process heating demand |
|
Heating system distribution losses |
|
Heating system emission losses |
|
Sensible heating system demand |
|
AHU latent heating demand |
|
ARU latent heating demand |
|
Total latent heating demand for all systems |
|
AHU sensible heating demand |
|
ARU sensible heating demand |
|
SHU sensible heating demand |
|
Total sensible heating demand |
|
Space heating demand in AHU |
|
Space heating demand in ARU |
|
End-use space heating demand, Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls |
|
SHU system heating demand |
|
DHW specific heating demand |
|
End-use hotwater demand |
|
Solar thermal energy requirement for space heating supply |
|
Solar thermal energy requirement for hotwater supply |
|
Outdoor temperature |
|
Indoor temperature |
|
Cooling supply temperature of the data centre |
|
Cooling return temperature of the data centre |
|
Cooling return temperature of the refrigeration system. |
|
Cooling supply temperature of the refrigeration system. |
|
Return temperature cooling system |
|
Return temperature cooling system |
|
System cooling return temperature. |
|
Return temperature cooling system |
|
Supply temperature cooling system |
|
Supply temperature cooling system |
|
System cooling supply temperature. |
|
Supply temperature cooling system |
|
Operative temperature in building (RC-model) used for comfort plotting |
|
Return temperature heating system |
|
Return temperature heating system |
|
Heating system return temperature. |
|
Return temperature heating system |
|
Supply temperature heating system |
|
Supply temperature heating system |
|
Heating system supply temperature. |
|
Supply temperature heating system |
|
Return temperature hotwater system |
|
Supply temperature hotwater system |
|
WOOD requirement for space heating supply |
|
WOOD requirement for hotwater supply |
|
Internal mass fraction of humidity (water/dry air) |
get_geothermal_potential
path: outputs/data/potentials/Shallow_geothermal_potential.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
areas available to install ground source heat pumps |
|
geothermal heat potential |
|
ground temperature |
get_lca_embodied
path: outputs/data/emissions/Total_LCA_embodied.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Gross floor area |
|
Embodied emissions per conditioned floor area due to building construction and decommissioning |
|
Embodied emissions due to building construction and decommissioning |
|
Unique building ID. It must start with a letter. |
get_lca_mobility
path: outputs/data/emissions/Total_LCA_mobility.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Gross floor area |
|
Operational emissions per unit of conditioned floor area due to mobility |
|
Operational emissions due to mobility |
|
Unique building ID. It must start with a letter. |
get_lca_operation
path: outputs/data/emissions/Total_LCA_operation.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Operational emissions per unit of conditioned floor area of the coal powererd heating system |
|
Operational emissions of the coal powered heating system |
|
Operational primary energy demand (non-renewable) for coal powered heating system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the coal powered heating system |
|
Operational emissions per unit of conditioned floor area of the coal powered domestic hot water system |
|
Operational emissions of the coal powered domestic hot water system |
|
Operational primary energy demand (non-renewable) for coal powered domestic hot water system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the coal powered domestic hot water system |
|
Operational emissions per unit of conditioned floor area of the district cooling for the data center |
|
Operational emissions of the district cooling for the data center |
|
Operational primary energy demand (non-renewable) for district cooling system for cool room refrigeration |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) for district cooling for cool room refrigeration |
|
Operational emissions per unit of conditioned floor area for district cooling system for cool room refrigeration |
|
Operational emissions for district cooling system for cool room refrigeration |
|
Operational primary energy demand (non-renewable) for district cooling system for cool room refrigeration |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) for cool room refrigeration |
|
Operational emissions per unit of conditioned floor area of the district cooling |
|
Operational emissions of the district cooling |
|
Operational primary energy demand (non-renewable) for district cooling system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the district cooling |
|
Operational emissions per unit of conditioned floor area of the district heating system |
|
Operational emissions of the district heating system |
|
Operational primary energy demand (non-renewable) for district heating system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the district heating system |
|
Operational emissions per unit of conditioned floor area of the district heating domestic hot water system |
|
Operational emissions of the district heating powered domestic hot water system |
|
Operational primary energy demand (non-renewable) for district heating powered domestic hot water system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the district heating domestic hot water system |
|
Gross floor area |
|
Total operational emissions per unit of conditioned floor area |
|
Total operational emissions |
|
Operational emissions per unit of conditioned floor area from grid electricity |
|
Operational emissions of the electrictiy from the grid |
|
Operational primary energy demand (non-renewable) from the grid |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) from grid electricity |
|
Unique building ID. It must start with a letter. |
|
Operational emissions per unit of conditioned floor area of the natural gas powered heating system |
|
Operational emissions of the natural gas powered heating system |
|
Operational primary energy demand (non-renewable) for natural gas powered heating system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the natural gas powered heating system |
|
Operational emissions per unit of conditioned floor area of the gas powered domestic hot water system |
|
Operational emissions of the solar powered domestic hot water system |
|
Operational primary energy demand (non-renewable) for natural gas powered domestic hot water system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the natural gas powered domestic hot water system |
|
Operational emissions per unit of conditioned floor area of the oil powered heating system |
|
Operational emissions of the oil powered heating system |
|
Operational primary energy demand (non-renewable) for oil powered heating system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the oil powered heating system |
|
Operational emissions per unit of conditioned floor area of the oil powered domestic hot water system |
|
Operational emissions of the oil powered domestic hot water system |
|
Operational primary energy demand (non-renewable) for oil powered domestic hot water system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the oil powered domestic hot water system |
|
Operational emissions per unit of conditioned floor area for PV-System |
|
Operational emissions of the PV-System |
|
Operational primary energy demand (non-renewable) for PV-System |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) for PV System |
|
Operational emissions per unit of conditioned floor area of the solar powered heating system |
|
Operational emissions of the solar powered heating system |
|
Operational primary energy demand (non-renewable) of the solar powered heating system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the solar powered heating system |
|
Operational emissions per unit of conditioned floor area of the solar powered domestic hot water system |
|
Operational emissions of the solar powered domestic hot water system |
|
Operational primary energy demand (non-renewable) for solar powered domestic hot water system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the solar poweed domestic hot water system |
|
Operational emissions per unit of conditioned floor area of the wood powered heating system |
|
Operational emissions of the wood powered heating system |
|
Operational primary energy demand (non-renewable) for wood powered heating system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the wood powered heating system |
|
Operational emissions per unit of conditioned floor area of the wood powered domestic hot water system |
|
Operational emissions of the wood powered domestic hot water system |
|
Operational primary energy demand (non-renewable) for wood powered domestic hot water system |
|
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the wood powered domestic hot water system |
get_multi_criteria_analysis
path: outputs/data/multicriteria/gen_2_multi_criteria_analysis.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital costs of building-scale systems |
|
Capital costs of district-scale systems |
|
Capital costs of all systems |
|
Capital costs of building-scale systems |
|
Capital costs of district-scale systems |
|
Capital costs of all systems |
|
Generation or iteration |
|
Rank for emissions |
|
Green house gas emissions of building-scale systems |
|
Green house gas emissions of building-scale systems |
|
Green house gas emissions of all systems |
|
system number |
|
Name of system |
|
normalization of CAPEX |
|
normalization of GHG |
|
Normalization of OPEX |
|
normalization of TAC |
|
Operational costs of building-scale systems |
|
Operational costs of district-scale systems |
|
Operational costs of all systems |
|
Rank of TAC |
|
Equivalent annual costs of building-scale systems |
|
Equivalent annual of district-scale systems |
|
Equivalent annual costs of all systems |
|
Best system according to user multi-criteria weights |
|
Rank of Best system according to user mult-criteria weights |
get_network_energy_pumping_requirements_file
path: outputs/data/thermal-network/DH__plant_pumping_load_kW.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
pumping electricity required to overcome pressure losses in the return network |
|
pumping electricity required to overcome pressure losses in the substations |
|
pumping electricity required to overcome pressure losses in the supply network |
|
pumping electricity required to overcome pressure losses in the entire network |
get_network_layout_edges_shapefile
path: outputs/data/thermal-network/DH/edges.shp
The following file is used by these scripts: thermal_network
Variable |
Description |
---|---|
|
Geometry |
|
length of this edge |
|
Unique network pipe ID. |
|
Classifies nominal pipe diameters (DN) into typical bins. |
|
Material type |
get_network_layout_nodes_shapefile
path: outputs/data/thermal-network/DH/nodes.shp
The following file is used by these scripts: thermal_network
Variable |
Description |
---|---|
|
Unique building ID. e.g. “B01” |
|
Geometry |
|
Unique node ID. e.g. “NODE1” |
|
Type of node. |
get_network_linear_pressure_drop_edges
path: outputs/data/thermal-network/DH__linear_pressure_drop_edges_Paperm.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
linear pressure drop in this pipe section |
get_network_linear_thermal_loss_edges_file
path: outputs/data/thermal-network/DH__linear_thermal_loss_edges_Wperm.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
linear thermal losses in this pipe section |
get_network_pressure_at_nodes
path: outputs/data/thermal-network/DH__pressure_at_nodes_Pa.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
pressure at this node |
get_network_temperature_plant
path: outputs/data/thermal-network/DH__temperature_plant_K.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Plant return temperature at each time step |
|
Plant supply temperature at each time step |
get_network_temperature_return_nodes_file
path: outputs/data/thermal-network/DH__temperature_return_nodes_K.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Return temperature at node NODE0 (outlet temperature of NODE0) at each time step |
get_network_temperature_supply_nodes_file
path: outputs/data/thermal-network/DH__temperature_supply_nodes_K.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Supply temperature at node NODE0 (inlet temperature of NODE0) at each time step |
get_network_thermal_loss_edges_file
path: outputs/data/thermal-network/DH__thermal_loss_edges_kW.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal losses along pipe PIPE0 at each time step |
get_network_total_pressure_drop_file
path: outputs/data/thermal-network/DH__plant_pumping_pressure_loss_Pa.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Pressure losses in the return network at each time step |
|
Pressure losses in all substations at each time step |
|
Pressure losses in the supply network at each time step |
|
Total pressure losses in the entire thermal network at each time step |
get_network_total_thermal_loss_file
path: outputs/data/thermal-network/DH__total_thermal_loss_edges_kW.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Thermal losses in the supply network at each time step |
|
Thermal losses in the return network at each time step |
|
Thermal losses in the entire thermal network at each time step |
get_nominal_edge_mass_flow_csv_file
path: outputs/data/thermal-network/Nominal_EdgeMassFlow_at_design_{network_type}__kgpers.csv
The following file is used by these scripts: thermal_network
Variable |
Description |
---|---|
|
Mass flow rate in pipe PIPE0 at design operating conditions |
get_nominal_node_mass_flow_csv_file
path: outputs/data/thermal-network/Nominal_NodeMassFlow_at_design_{network_type}__kgpers.csv
The following file is used by these scripts: thermal_network
Variable |
Description |
---|---|
|
Mass flow rate in node NODE0 at design operating conditions |
get_optimization_building_scale_cooling_capacity
path: outputs/data/optimization/slave/gen_1/ind_0_building_scale_cooling_capacity.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal Capacity of Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
|
Thermal Capacity of High-Temperature Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
|
Thermal Capacity of Base load Vapor Compression Chiller for Decentralized Building |
|
Thermal Capacity of Direct Expansion Air-Source for Decentralized Building |
|
Thermal Capacity of High-Temperature Vapor Compression Chiller (Air-Source) for Decentralized Building |
|
Thermal Capacity of Absorption Chiller and Solar Collector (Evacuated Tube)for Decentralized Building |
|
Unique building ID. It must start with a letter |
get_optimization_building_scale_heating_capacity
path: outputs/data/optimization/slave/gen_0/ind_1_building_scale_heating_capacity.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal capacity of Base load boiler for Decentralized building |
|
Thermal capacity of Fuel Cell for Decentralized building |
|
Thermal capacity of ground-source heat pump for Decentralized building |
|
Unique building ID. It must start with a letter |
get_optimization_checkpoint
path: outputs/data/optimization/master/CheckPoint_1
The following file is used by these scripts:
Variable |
Description |
---|---|
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
get_optimization_decentralized_folder_building_result_cooling
path: outputs/data/optimization/decentralized/{building}_{configuration}_cooling.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Index of best configuration simulated |
|
Thermal Capacity of Absorption Chiller connected to Flat-plate Solar Collector |
|
Thermal Capacity of High Temperature Absorption Chiller connected to Solar Collector (flat Plate) |
|
Thermal Capacity of Base Vapor compression chiller (air-source) |
|
Thermal Capacity of Direct-Expansion Unit Air-source |
|
Thermal Capacity of High Temperature Vapor compression chiller (air-source) |
|
Thermal Capacity of Absorption Chiller connected to Evacuated-Tube Solar Collector |
|
Annualized Capital Costs |
|
Total Capital Costs |
|
Annual Green House Gas Emissions |
|
Nominal heat load |
|
Fixed Annual Operational Costs |
|
Variable Annual Operational Costs |
|
Total Annualized Costs |
get_optimization_decentralized_folder_building_result_cooling_activation
path: outputs/data/optimization/decentralized/{building}_{configuration}_cooling_activation.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Electricity requirements of Absorption Chillers |
|
Electricity requirements of Vapor Compression Chillers and refrigeration |
|
Electricity requirements due to space cooling, servers cooling and refrigeration |
|
Electricity requirements of Cooling Towers |
|
Electricity requirements of Air-Source direct expansion chillers |
|
Electricity requirements of Solar Collectors (evacuated-tubes) |
|
Electricity requirements of Solar Collectors (flat-plate) |
|
Requirements of Natural Gas for Boilers |
|
Requirements of Natural Gas for Burners |
|
Thermal energy generated by Absorption chillers |
|
Thermal energy generated by Air-Source Vapor-compression chillers |
|
Thermal energy generated by Natural gas Boilers to Absorption chillers |
|
Thermal energy generated by Natural gas Burners to Absorption chillers |
|
Thermal energy generated by Air-Source direct expansion chillers |
|
Thermal energy generated by Solar Collectors (evacuated-tubes) to Absorption chillers |
|
Thermal energy generated by Solar Collectors (flat-plate) to Absorption chillers |
get_optimization_decentralized_folder_building_result_heating
path: outputs/data/optimization/decentralized/DiscOp_B001_result_heating.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Index of best configuration simulated |
|
Thermal capacity of Baseload Boiler NG |
|
Thermal Capacity of Fuel Cell NG |
|
Thermal Capacity of Ground Source Heat Pump |
|
Annualized Capital Costs |
|
Total Capital Costs |
|
Annual Green House Gas Emissions |
|
Nominal heat load |
|
Fixed Annual Operational Costs |
|
Variable Annual Operational Costs |
|
Total Annualized Costs |
get_optimization_decentralized_folder_building_result_heating_activation
path: outputs/data/optimization/decentralized/DiscOp_B001_result_heating_activation.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Status of the BackupBoiler (1=on, 0 =off) |
|
Requirements of Bio-gas for Base load Boiler |
|
Status of the Base load Boiler (1=on, 0 =off) |
|
Electricity generation of fuel cell exported to the grid |
|
Electricity Requirements for heat pump compressor and auxiliary uses (if required) |
|
Status of the fuel cell (1=on, 0 =off) |
|
Status of the ground-source heat pump (1=on, 0 =off) |
|
Requirements of Natural Gas for Back-up Boiler |
|
Requirements of Natural Gas for Base load Boiler |
|
Requirements of Natural Gas for fuel cell |
|
Thermal generation of Back-up Boiler to direct load |
|
Thermal generation of Base load Boiler to direct load |
|
Thermal generation of fuel cell to direct load |
|
Thermal generation of ground-source heat pump to direct load |
get_optimization_district_scale_cooling_capacity
path: outputs/data/optimization/slave/gen_1/ind_1_district_scale_cooling_capacity.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal Capacity of Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
|
Thermal Capacity of High-Temperature Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
|
Thermal Capacity of Base load Vapor Compression Chiller for Decentralized Building |
|
Thermal Capacity of Direct Expansion Air-Source for Decentralized Building |
|
Thermal Capacity of High-Temperature Vapor Compression Chiller (Air-Source) for Decentralized Building |
|
Thermal Capacity of Absorption Chiller and Solar Collector (Evacuated Tube)for Decentralized Building |
|
Unique building ID. It must start with a letter |
get_optimization_district_scale_electricity_capacity
path: outputs/data/optimization/slave/gen_2/ind_0_district_scale_electrical_capacity.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Electrical Capacity Required from the local Grid |
|
Area Coverage of PV in central Plant |
|
Electrical Capacity of PV in central Plant |
get_optimization_district_scale_heating_capacity
path: outputs/data/optimization/slave/gen_0/ind_2_district_scale_heating_capacity.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal Capacity of Back-up Boiler - Natural Gas in central plant |
|
Thermal Capacity of Base Load Boiler - Natural Gas in central plant |
|
Electrical Capacity of CHP Dry-Biomass in central plant |
|
ThermalCapacity of CHP Dry-Biomass in central plant |
|
Electrical Capacity of CHP Natural-Gas in central plant |
|
Thermal Capacity of CHP Natural-Gas in central plant |
|
Electrical Capacity of CHP Wet-Biomass in central plant |
|
Thermal Capacity of CHP Wet-Biomass in central plant |
|
Thermal Capacity of Heat Pump Server-Source in central plant |
|
Thermal Capacity of Heat Pump Ground-Source in central plant |
|
Thermal Capacity of Heat Pump Sewage-Source in central plant |
|
Thermal Capacity of Heat Pump Water-Source in central plant |
|
Thermal Capacity of Peak Boiler - Natural Gas in central plant |
|
Electrical Capacity of PVT Field in central plant |
|
Thermal Capacity of PVT panels in central plant |
|
Thermal Capacity of Solar Collectors (Evacuated-tube) in central plant |
|
Thermal Capacity of Solar Collectors (Flat-plate) in central plant |
|
Thermal Capacity of Seasonal Thermal Storage in central plant |
get_optimization_generation_building_scale_performance
path: outputs/data/optimization/slave/gen_2/gen_2_building_scale_performance.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital Costs of building-scale systems due to cooling |
|
Annualized Capital Costs of building-scale systems due to heating |
|
Total Capital Costs of building-scale systems due to cooling |
|
Total Capital Costs of building-scale systems due to heating |
|
No. Generation or Iteration (genetic Algorithm) |
|
Green House Gas Emissions of building-scale systems due to Cooling |
|
Green House Gas Emissions of building-scale systems due to Heating |
|
No. Individual unique ID |
|
Name of Individual unique ID |
|
Fixed Operational Costs of building-scale systems due to cooling |
|
Fixed Operational Costs of building-scale systems due to heating |
|
Variable Operational Costs of building-scale systems due to cooling |
|
Variable Operational Costs of building-scale systems due to heating |
get_optimization_generation_district_scale_performance
path: outputs/data/optimization/slave/gen_1/gen_1_district_scale_performance.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital Costs of Back-up Boiler Natural Gas in Central Plant |
|
Annualized Capital Costs of Base Load Boiler Boiler Natural Gas in Central Plant |
|
Annualized Capital Costs of CHP Natural Gas in Central Plant |
|
Annualized Capital Costs of District Heating Network |
|
Annualized Capital Costs of CHP Dry-Biomass in Central Plant |
|
Annualized Capital Costs of CHP Wet-Biomass in Central Plant |
|
Annualized Capital Costs of Ground-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of connection to local electrical grid |
|
Annualized Capital Costs of Lake-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of Server-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of Sewage-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of Peak Load Boiler Boiler Natural Gas in Central Plant |
|
Annualized Capital Costs of Photovoltaic Panels in Central Plant |
|
Annualized Capital Costs of PVT Panels in Central Plant |
|
Annualized Capital Costs of Solar Collectors (evacuated-Tube) in Central Plant |
|
Annualized Capital Costs of Solar Collectors (Flat-Plate) in Central Plant |
|
Annualized Capital Costs of Seasonal Thermal Storage in Central Plant |
|
Annualized Capital Costs of Thermal Substations |
|
Total Capital Costs of Back-up Boiler Natural Gas in Central Plant |
|
Total Capital Costs of Base Load Boiler Boiler Natural Gas in Central Plant |
|
Total Capital Costs of CHP Natural Gas in Central Plant |
|
Total Capital Costs of District Heating Network |
|
Total Capital Costs of CHP Dry-Biomass in Central Plant |
|
Total Capital Costs of CHP Wet-Biomass in Central Plant |
|
Total Capital Costs of Ground-Source Heat Pump in Central Plant |
|
Total Capital Costs of connection to local electrical grid |
|
Total Capital Costs of Lake-Source Heat Pump in Central Plant |
|
Total Capital Costs of Server-Source Heat Pump in Central Plant |
|
Total Capital Costs of Sewage-Source Heat Pump in Central Plant |
|
Total Capital Costs of Peak Load Boiler Boiler Natural Gas in Central Plant |
|
Total Capital Costs of Photovoltaic Panels in Central Plant |
|
Total Capital Costs of PVT Panels in Central Plant |
|
Total Capital Costs of Solar Collectors (evacuated-Tube) in Central Plant |
|
Total Capital Costs of Solar Collectors (Flat-Plate) in Central Plant |
|
Total Capital Costs of Seasonal Thermal Storage in Central Plant |
|
Total Capital Costs of Thermal Substations |
|
Number of the Generation or Iteration (Genetic algorithm) |
|
Green House Gas Emissions of Dry-Biomass of district-scale systems |
|
Green House Gas Emissions of Exports of Electricity |
|
Green House Gas Emissions of Import of Electricity |
|
Green House Gas Emissions of Natural Gas of district-scale systems |
|
Green House Gas Emissions of Wet-Biomass of district-scale systems |
|
Unique numerical ID of individual |
|
Unique alphanumerical ID of individual |
|
Fixed Operation Costs of Back-up Boiler Natural Gas in Central Plant |
|
Fixed Operation Costs of Base Load Boiler Boiler Natural Gas in Central Plant |
|
Fixed Operation Costs of CHP Natural Gas in Central Plant |
|
Fixed Operation Costs of District Heating Network |
|
Fixed Operation Costs of CHP Dry-Biomass in Central Plant |
|
Fixed Operation Costs of CHP Wet-Biomass in Central Plant |
|
Fixed Operation Costs of Ground-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Electricity in Buildings Connected to Central Plant |
|
Fixed Operation Costs of Lake-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Server-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Sewage-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Peak Load Boiler Boiler Natural Gas in Central Plant |
|
Fixed Operation Costs of Photovoltaic Panels in Central Plant |
|
Fixed Operation Costs of PVT Panels in Central Plant |
|
Fixed Operation Costs of Solar Collectors (evacuated-Tube) in Central Plant |
|
Fixed Operation Costs of Solar Collectors (Flat-Plate) in Central Plant |
|
Fixed Operation Costs of Seasonal Thermal Storage in Central Plant |
|
Fixed Operation Costs of Thermal Substations |
|
Variable Operation Costs due to consumption of Dry-Biomass in Central Plant |
|
Variable Operation Costs due to electricity exported |
|
Variable Operation Costs due to electricity imported |
|
Variable Operation Costs due to consumption of Natural Gas in Central Plant |
|
Variable Operation Costs due to consumption of Wet-Biomass in Central Plant |
get_optimization_generation_total_performance
path: outputs/data/optimization/slave/gen_2/gen_2_total_performance.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital Costs of building-scale systems |
|
Annualized Capital Costs of district-scale systems |
|
Annualized Capital Costs of all systems |
|
Total Capital Costs of building-scale systems |
|
Total Capital Costs of district-scale systems |
|
Total Capital Costs of district-scale systems and Decentralized Buildings |
|
No. Generation or Iteration (genetic Algorithm) |
|
Green House Gas Emissions of building-scale systems |
|
Green House Gas Emissions Central Plant |
|
Green House Gas Emissions of all systems |
|
No. Individual unique ID |
|
Name of Individual unique ID |
|
Operation Costs of building-scale systems |
|
Operation Costs of district-scale systems |
|
Operation Costs of all systems |
|
Total Anualized Costs of building-scale systems |
|
Total Anualized Costs of district-scale systems |
|
Total Anualized Costs of all systems |
get_optimization_generation_total_performance_pareto
path: outputs/data/optimization/slave/gen_2/gen_2_total_performance_pareto.csv
The following file is used by these scripts: multi_criteria_analysis
Variable |
Description |
---|---|
|
Annualized Capital Costs of building-scale systems |
|
Annualized Capital Costs of district-scale systems |
|
Annualized Capital Costs of all systems |
|
Total Capital Costs of building-scale systems |
|
Total Capital Costs of district-scale systems |
|
Total Capital Costs of district-scale systems and Decentralized Buildings |
|
No. Generation or Iteration (genetic Algorithm) |
|
Green House Gas Emissions of building-scale systems |
|
Green House Gas Emissions Central Plant |
|
Green House Gas Emissions of all systems |
|
No. Individual unique ID |
|
Name of Individual unique ID |
|
Operation Costs of building-scale systems |
|
Operation Costs of district-scale systems |
|
Operation Costs of all systems |
|
Total Anualized Costs of building-scale systems |
|
Total Anualized Costs of district-scale systems |
|
Total Anualized Costs of all systems |
get_optimization_individuals_in_generation
path: outputs/data/optimization/slave/gen_2/generation_2_individuals.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
get_optimization_network_results_summary
path: outputs/data/optimization/network/DH_Network_summary_result_0x1be.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Time stamp (hourly) for one year |
|
Capacity mass flow rate for server cooling of this network |
|
Total mass flow rate in this district heating network |
|
Thermal losses of this district heating network |
|
Total thermal demand of district heating network |
|
Thermal Demand for server cooling in this network |
|
Average Temperature of return of this district heating network |
|
Average Temperature of supply of this district heating network |
get_optimization_slave_building_connectivity
path: outputs/data/optimization/slave/gen_2/ind_1_building_connectivity.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Flag to know if building is connected to District Heating or not |
|
Flag to know if building is connected to District Cooling or not |
|
Unique building ID. It must start with a letter.) |
get_optimization_slave_building_scale_performance
path: outputs/data/optimization/slave/gen_2/ind_0_buildings_building_scale_performance.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital Costs of building-scale systems due to cooling |
|
Annualized Capital Costs of building-scale systems due to heating |
|
Total Capital Costs of building-scale systems due to cooling |
|
Total Capital Costs of building-scale systems due to heating |
|
Green House Gas Emissions of building-scale systems due to Cooling |
|
Green House Gas Emissions of building-scale systems due to Heating |
|
Fixed Operational Costs of building-scale systems due to cooling |
|
Fixed Operational Costs of building-scale systems due to heating |
|
Variable Operational Costs of building-scale systems due to cooling |
|
Variable Operational Costs of building-scale systems due to heating |
get_optimization_slave_cooling_activation_pattern
path: outputs/data/optimization/slave/gen_1/ind_2_Cooling_Activation_Pattern.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Installed capacity of the short-term thermal storage |
|
Annualized capital costs of the short-term thermal storage |
|
Total capital costs of the short-term thermal storage |
|
Fixed operational costs of the short-term thermal storage |
|
Thermal energy content of the short-term thermal storage |
|
Thermal energy supplied from the short-term thermal storage |
get_optimization_slave_district_scale_performance
path: outputs/data/optimization/slave/gen_1/ind_2_buildings_district_scale_performance.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital Costs of Back-up Boiler Natural Gas in Central Plant |
|
Annualized Capital Costs of Base load Boiler Natural Gas in Central Plant |
|
Annualized Capital Costs of CHP Natural Gas in Central Plant |
|
Annualized Capital Costs of District Heating Network |
|
Annualized Capital Costs of CHP Dry-Biomass in Central Plant |
|
Annualized Capital Costs of CHP Wet-Biomass in Central Plant |
|
Annualized Capital Costs of Ground-Source Heat-Pump in Central Plant |
|
Annualized Capital Costs of connection to local grid |
|
Annualized Capital Costs of Lake-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of Server-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of Sewage-Source Heat Pump in Central Plant |
|
Annualized Capital Costs of Peak Boiler in Central Plant |
|
Annualized Capital Costs of PV panels |
|
Annualized Capital Costs of PVT panels |
|
Annualized Capital Costs of Solar collectors (evacuated Tubes) |
|
Annualized Capital Costs of Solar collectors (Flat-Plate) |
|
Annualized Capital Costs of Seasonal Thermal Storage in Central Plant |
|
Annualized Capital Costs of Heating Substations |
|
Total Capital Costs of Back-up Boiler Natural Gas in Central Plant |
|
Total Capital Costs of Base load Boiler Natural Gas in Central Plant |
|
Total Capital Costs of CHP Natural Gas in Central Plant |
|
Total Capital Costs of District Heating Network |
|
Total Capital Costs of CHP Dry-Biomass in Central Plant |
|
Total Capital Costs of CHP Wet-Biomass in Central Plant |
|
Total Capital Costs of Ground-Source Heat-Pump in Central Plant |
|
Total Capital Costs of connection to local grid |
|
Total Capital Costs of Lake-Source Heat Pump in Central Plant |
|
Total Capital Costs of Server-Source Heat Pump in Central Plant |
|
Total Capital Costs of Sewage-Source Heat Pump in Central Plant |
|
Total Capital Costs of Peak Boiler in Central Plant |
|
Total Capital Costs of PV panels |
|
Total Capital Costs of PVT panels |
|
Total Capital Costs of Solar collectors (evacuated Tubes) |
|
Total Capital Costs of Solar collectors (Flat-Plate) |
|
Total Capital Costs of Seasonal Thermal Storage |
|
Total Capital Costs of Heating Substations |
|
Green House Gas Emissions of Dry-Biomass in Central plant |
|
Green House Gas Emissions of Electricity Exports in Central Plant |
|
Green House Gas Emissions of Electricity Import in Central Plant |
|
Green House Gas Emissions of Natural Gas in Central plant |
|
Green House Gas Emissions of Wet-Biomass in Central plant |
|
Fixed Operation Costs of Back-up Boiler Natural Gas in Central Plant |
|
Fixed Operation Costs of Base load Boiler Natural Gas in Central Plant |
|
Fixed Operation Costs of CHP Natural Gas in Central Plant |
|
Fixed Operation Costs of District Heating Network |
|
Fixed Operation Costs of CHP Dry-Biomass in Central Plant |
|
Fixed Operation Costs of CHP Wet-Biomass in Central Plant |
|
Fixed Operation Costs of Ground-Source Heat-Pump in Central Plant |
|
Fixed Operation Costs of connection to local grid |
|
Fixed Operation Costs of Lake-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Server-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Sewage-Source Heat Pump in Central Plant |
|
Fixed Operation Costs of Peak Boiler in Central Plant |
|
Fixed Operation Costs of PV panels |
|
Fixed Operation Costs of PVT panels |
|
Fixed Operation Costs of Solar collectors (evacuated Tubes) |
|
Fixed Operation Costs of Solar collectors (Flat-Plate) |
|
Fixed Operation Costs of Seasonal Thermal Storage |
|
Fixed Operation Costs of Heating Substations |
|
Variable Operation Costs |
|
Variable Operation Costs |
|
Variable Operation Costs |
|
Variable Operation Costs |
|
Variable Operation Costs |
get_optimization_slave_electricity_activation_pattern
path: outputs/data/optimization/slave/gen_1/ind_1_Electricity_Activation_Pattern.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Time stamp (hourly) for one year |
|
Electricity Generated to direct load by CHP Natural Gas |
|
Electricity Exported by CHP Natural Gas |
|
Electricity Generated to direct load by CHP Dry Biomass |
|
Electricity Exported by CHP Dry Biomass |
|
Electricity Generated to direct load by CHP Wet Biomass |
|
Electricity Exported by CHP Wet Biomass |
|
Electricity Imported from the local grid |
|
Electricity Generated to direct load by PV panels |
|
Electricity Exported by PV panels |
|
Electricity Generated to direct load by PVT panels |
|
Electricity Exported by PVT panels |
|
Electricity Generated to direct load by Trigen CHP Natural Gas |
|
Electricity Exported by Trigen CHP Natural Gas |
get_optimization_slave_electricity_requirements_data
path: outputs/data/optimization/slave/gen_1/ind_1_Electricity_Requirements_Pattern.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Time stamp (hourly) for one year |
|
Electricity (auxiliary) Required by Back-up Boiler |
|
Electricity Required by Back-up Vapor Compression Chiller (Air-Source) |
|
Electricity (auxiliary) Required by Base Load Boiler |
|
Electricity Required by Base Load Vapor Compression Chiller (Air-Source) |
|
Electricity Required by Base Load Vapor Compression Chiller (Water-Source) |
|
Electricity Required for space cooling, server cooling and refrigeration of building-scale systems |
|
Electricity Required for space cooling, server cooling and refrigeration of Buildings Connected to Network |
|
Electricity Required for Chilled water Pumping in District Cooling Network |
|
Electricity Required for Chilled water Pumping in District Heating Network |
|
Total Electricity Requirements |
|
Electricity Required by Ground-Source Heat Pumps |
|
Electricity Required by Lake-Source Heat Pumps |
|
Electricity Required by Auxiliary Heat Pumps of PVT panels |
|
Electricity Required by Auxiliary Heat Pumps of Solar collectors (Evacuated tubes) |
|
Electricity Required by Auxiliary Heat Pumps of Solar collectors (Evacuated Flat Plate) |
|
Electricity Required by Server-Source Heat Pumps |
|
Electricity Required by Sewage-Source Heat Pumps |
|
Electricity Required for space heating and hotwater of building-scale systems |
|
Electricity Required for space heating and hotwater of Buildings Connected to Network |
|
Electricity (auxiliary) Required by Peak-Boiler |
|
Electricity Required by Peak Vapor Compression Chiller (Air-Source) |
|
Electricity Required by Peak Vapor Compression Chiller (Water-Source) |
|
Electricity Required by Auxiliary Heatpumps for charging Seasonal Thermal Storage |
|
Electricity Required by Auxiliary Heatpumps for discharging Seasonal Thermal Storage |
|
Electricity Required for Appliances and Lighting in all Buildings |
|
Electricity Required for Fans and others in all Buildings |
|
Electricity Required for Servers in all Buildings |
|
Electricity Required for Industrial Processes in all Buildings |
get_optimization_slave_heating_activation_pattern
path: outputs/data/optimization/slave/gen_2/ind_0_Heating_Activation_Pattern.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Time stamp (hourly) for one year |
|
Electricity Generation by CHP Natural Gas |
|
Electricity Generation by CHP Dry-Biomass |
|
Electricity Generation by CHP Wet-Biomass |
|
Electricity Generation by PVT |
|
Thermal generation of Back-up Boiler to direct load |
|
Thermal generation of Base load Boiler to direct load |
|
Thermal generation of CHP Natural Gas to direct load |
|
Thermal requirements of District Heating Network |
|
Thermal generation of CHP Dry-Biomass to direct load |
|
Thermal generation of CHP Wet-Biomass to direct load |
|
Thermal generation of ground-source heat pump to direct load |
|
Thermal generation of Lake-Source Heatpump to direct load |
|
Thermal generation of Server-Source Heatpump to direct load |
|
Thermal generation of Server-Source Heatpump to Seasonal Thermal Storage |
|
Thermal generation of Sewage-Source Heatpump to direct load |
|
Thermal generation of Peak Boiler to direct load |
|
Thermal generation of PVT to direct load |
|
Thermal generation of PVT to Seasonal Thermal Storage |
|
Thermal generation of Solar Collectors (Evacuated Tubes) to direct load |
|
Thermal generation of Solar Collectors (Evacuated Tubes) to Seasonal Thermal Storage |
|
Thermal generation of Solar Collectors (Flat Plate) to direct load |
|
Thermal generation of Solar Collectors (Flat Plate) to Seasonal Thermal Storage |
|
Discharge from Storage to Direct Load |
get_optimization_slave_total_performance
path: outputs/data/optimization/slave/gen_0/ind_2_total_performance.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Annualized Capital Costs of building-scale systems |
|
Annualized Capital Costs of district-scale systems |
|
Annualized Capital Costs of all systems |
|
Total Capital Costs of building-scale systems |
|
Total Capital Costs of district-scale systems |
|
Total Capital Costs of all systems |
|
Green House Gas Emissions of building-scale systems |
|
Green House Gas Emissions Central Plant |
|
Green House Gas Emissions of all systems |
|
Operation Costs of building-scale systems |
|
Operation Costs of district-scale systems |
|
Operation Costs of all systems |
|
Total Anualized Costs of building-scale systems |
|
Total Anualized Costs of district-scale systems |
|
Total Anualized Costs of all systems |
get_optimization_substations_results_file
path: outputs/data/optimization/substations/110011011DH_B001_result.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Substation heat exchanger area to supply domestic hot water |
|
Substation heat exchanger area to supply space heating |
|
Substation flow rate on the DH side. |
|
Substation heat requirement to supply domestic hot water |
|
Substation heat requirement to supply space heating |
|
Substation return temperature of the district heating network |
|
Substation supply temperature of the district heating network. |
get_optimization_substations_total_file
path: outputs/data/optimization/substations/Total_DH_111111111.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Conditioned floor area (heated/cooled) |
|
Occupied floor area (heated/cooled) |
|
Roof area |
|
Nominal Coal requirement for space heating supply |
|
Coal requirement for space heating supply |
|
Nominal Coal requirement for hotwater supply |
|
Coal requirement for hotwater supply |
|
Nominal district cooling for final data center cooling demand |
|
District cooling for data center cooling demand |
|
Nominal district cooling for refrigeration demand |
|
District cooling for refrigeration demand |
|
Nominal district cooling for space cooling demand |
|
Energy consumption of space cooling system (if supplied by District Cooling), DC_cs = Qcs_sys / eff_cs |
|
Nominal energy requirement by district heating (space heating supply) |
|
Energy requirement by district heating (space heating supply) |
|
Nominal Energy requirement by district heating (hotwater supply) |
|
Energy requirement by district heating (hotwater supply) |
|
Nominal Data centre cooling specific electricity consumption. |
|
Electricity consumption due to data center cooling |
|
Nominal Refrigeration system electricity consumption. |
|
Electricity consumption due to refrigeration |
|
Nominal Cooling system electricity consumption. |
|
Energy consumption of cooling system (if supplied by electricity grid), E_cs = Qcs_sys / eff_cs |
|
Nominal Heating system electricity consumption. |
|
Electricity consumption due to space heating |
|
Nominal end-use electricity demand |
|
End-use total electricity consumption, E_sys = Eve + Ea + El + Edata + Epro + Eaux + Ev |
|
Nominal Domestic hot water electricity consumption. |
|
Electricity consumption due to hot water |
|
Nominal end-use electricity for appliances |
|
End-use electricity for appliances |
|
Nominal Total net electricity for all sources and sinks. |
|
End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W |
|
Nominal Auxiliary electricity consumption. |
|
End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux |
|
Nominal Data centre electricity consumption. |
|
Electricity consumption for data centers |
|
Nominal end-use electricity for lights |
|
End-use electricity for lights |
|
Nominal Industrial processes electricity consumption. |
|
Electricity supplied to industrial processes |
|
Nominal end-use electricity for electric vehicles |
|
End-use electricity for electric vehicles |
|
Nominal end-use electricity for ventilation |
|
End-use electricity for ventilation |
|
Gross floor area |
|
Nominal Grid electricity consumption |
|
Nominal grid electricity requirements for appliances |
|
Grid electricity requirements for appliances |
|
Nominal grid electricity requirements for auxiliary loads |
|
Grid electricity requirements for auxiliary loads |
|
Nominal grid electricity requirements for servers cooling |
|
Grid electricity requirements for servers cooling |
|
Nominal grid electricity requirements for refrigeration |
|
Grid electricity requirements for refrigeration |
|
Nominal grid electricity requirements for space cooling |
|
Grid electricity requirements for space cooling |
|
Nominal grid electricity requirements for servers |
|
Grid electricity requirements for servers |
|
Nominal grid electricity requirements for space heating |
|
Grid electricity requirements for space heating |
|
Nominal grid electricity consumption for lights |
|
Grid electricity requirements for lights |
|
Grid electricity consumption, GRID = GRID_a + GRID_l + GRID_v + GRID_ve + GRID_data + GRID_pro + GRID_aux + GRID_ww + GRID_cs + GRID_hs + GRID_cdata + GRID_cre |
|
Nominal grid electricity requirements for industrial processes |
|
Grid electricity requirements for industrial processes |
|
Nominal grid electricity consumption for electric vehicles |
|
Grid electricity requirements for electric vehicles |
|
Nominal grid electricity consumption for ventilatioon |
|
Grid electricity requirements for ventilatioon |
|
Nominal grid electricity requirements for hot water supply |
|
Grid electricity requirements for hot water supply |
|
Unique building ID. It must start with a letter. |
|
Nominal NG requirement for space heating supply |
|
NG requirement for space heating supply |
|
Nominal NG requirement for hotwater supply |
|
NG requirement for hotwater supply |
|
Nominal OIL requirement for space heating supply |
|
OIL requirement for space heating supply |
|
Nominal OIL requirement for hotwater supply |
|
OIL requirement for hotwater supply |
|
Nominal occupancy |
|
Nominal PV electricity consumption |
|
PV electricity consumption |
|
Nominal Total system cooling demand. |
|
Total system cooling demand, QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys |
|
Nominal Data centre cooling demand. |
|
Data centre cooling demand |
|
Nominal end-use data center cooling demand |
|
End-use data center cooling demand |
|
Nominal process cooling demand. |
|
Yearly processes cooling demand. |
|
Nominal Refrigeration cooling demand. |
|
Refrigeration cooling demand for the system |
|
|
|
End-use refrigeration demand |
|
Nominal Total cooling demand. |
|
Nominal Cooling distribution losses. |
|
Cooling distribution losses |
|
Nominal Cooling emission losses. |
|
Cooling emission losses |
|
Nominal AHU latent cooling demand. |
|
AHU latent cooling demand |
|
Nominal ARU latent cooling demand. |
|
ARU latent cooling demand |
|
Nominal System latent cooling demand. |
|
System latent cooling demand |
|
Total cooling demand |
|
Nominal AHU system cooling demand. |
|
Sensible cooling demand in AHU |
|
Nominal ARU system cooling demand. |
|
ARU system cooling demand |
|
Nominal SCU system cooling demand. |
|
SCU system cooling demand |
|
Nominal Sensible system cooling demand. |
|
Total sensible cooling demand |
|
Nominal end-use space cooling demand |
|
Nominal AHU system cooling demand. |
|
AHU system cooling demand |
|
Nominal ARU system cooling demand. |
|
ARU system cooling demand |
|
End-use space cooling demand, Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls |
|
Nominal SCU system cooling demand. |
|
SCU system cooling demand |
|
Nominal total building heating demand. |
|
Total building heating demand |
|
Nominal process heating demand. |
|
Yearly processes heating demand. |
|
Nominal space heating demand. |
|
Nominal Heating system distribution losses. |
|
Heating system distribution losses |
|
Nominal Heating emission losses. |
|
Heating system emission losses |
|
Nominal AHU latent heating demand. |
|
AHU latent heating demand |
|
Nominal ARU latent heating demand. |
|
ARU latent heating demand |
|
Nominal System latent heating demand. |
|
System latent heating demand |
|
Total space heating demand. |
|
Nominal AHU sensible heating demand. |
|
AHU sensible heating demand |
|
ARU sensible heating demand |
|
ARU sensible heating demand |
|
Nominal SHU sensible heating demand. |
|
SHU sensible heating demand |
|
Nominal HVAC systems sensible heating demand. |
|
SHU sensible heating demand |
|
Nominal end-use space heating demand |
|
Nominal AHU sensible heating demand. |
|
AHU system heating demand |
|
Nominal ARU sensible heating demand. |
|
ARU sensible heating demand |
|
End-use space heating demand, Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls |
|
Nominal SHU sensible heating demand. |
|
SHU sensible heating demand |
|
Nominal DHW heating demand. |
|
DHW heating demand |
|
Nominal end-use hotwater demand |
|
End-use hotwater demand |
|
Nominal solar thermal energy requirement for space heating supply |
|
Solar thermal energy requirement for space heating supply |
|
Nominal solar thermal energy requirement for hotwater supply |
|
Solar thermal energy requirement for hotwater supply |
|
Nominal WOOD requirement for space heating supply |
|
WOOD requirement for space heating supply |
|
Nominal WOOD requirement for hotwater supply |
|
WOOD requirement for hotwater supply |
get_radiation_building
path: outputs/data/solar-radiation/{building}_radiation.csv
The following file is used by these scripts: demand
, photovoltaic
, photovoltaic_thermal
, solar_collector
Variable |
Description |
---|---|
|
Date and time in hourly steps |
|
solar incident on the roof tops |
|
roof top area |
|
solar incident on the east facing facades excluding windows |
|
area of the east facing facades excluding windows |
|
solar incident on the north facing facades excluding windows |
|
area of the north facing facades excluding windows |
|
solar incident on the south facing facades excluding windows |
|
area of the south facing facades excluding windows |
|
solar incident on the west facing facades excluding windows |
|
area of the south facing facades excluding windows |
|
solar incident on windows on the south facing facades |
|
window area on the east facing facades |
|
solar incident on windows on the south facing facades |
|
window area on the north facing facades |
|
solar incident on windows on the south facing facades |
|
window area on the south facing facades |
|
solar incident on windows on the west facing facades |
|
window area on the west facing facades |
get_radiation_building_sensors
path: outputs/data/solar-radiation/B001_insolation_Whm2.json
The following file is used by these scripts: demand
, photovoltaic
, photovoltaic_thermal
, solar_collector
Variable |
Description |
---|---|
|
TODO |
get_radiation_materials
path: outputs/data/solar-radiation/buidling_materials.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Solar heat gain coefficient. Defined according to ISO 13790. |
|
Unique building ID. It must start with a letter. |
|
Reflectance in the Red spectrum. Defined according Radiance. (long-wave) |
|
Reflectance in the Red spectrum. Defined according Radiance. (long-wave) |
|
Basement floor construction assembly (relates to “code” in ENVELOPE assemblies) |
|
Internal floor construction assembly (relates to “code” in ENVELOPE assemblies) |
|
Roof construction assembly (relates to “code” in ENVELOPE assemblies) |
|
External wall construction assembly (relates to “code” in ENVELOPE assemblies) |
|
Window assembly (relates to “code” in ENVELOPE assemblies) |
get_radiation_metadata
path: outputs/data/solar-radiation/B001_geometry.csv
The following file is used by these scripts: demand
, photovoltaic
, photovoltaic_thermal
, solar_collector
Variable |
Description |
---|---|
|
Surface area. |
|
Unique building ID. It must start with a letter. |
|
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
|
Orientation of the surface (north/east/south/west/top) |
|
Unique surface ID for each building exterior surface. |
|
Surface typology. |
|
Describes the position of the x vector. |
|
Directional scalar of the x vector. |
|
Describes the position of the y vector. |
|
Directional scalar of the y vector. |
|
Describes the position of the z vector. |
|
Directional scalar of the z vector. |
get_schedule_model_file
path: outputs/data/occupancy/B001.csv
The following file is used by these scripts: demand
Variable |
Description |
---|---|
|
Time stamp for each day of the year ascending in hourly intervals |
|
Electrical load due to processes |
|
Electrical load due to servers/data centers |
|
Electrical load due to lighting |
|
Electrical load due to processes |
|
Number of people in the building |
|
Process cooling load |
|
Cooling load due to cool room refrigeration |
|
Process heat load |
|
Sensible heat load of people |
|
Set point temperature of space cooling system |
|
Set point temperature of space heating system |
|
Ventilation rate |
|
Fresh water consumption (includes cold and hot water) |
|
Domestic hot water consumption |
|
Moisture released by occupants |
get_sewage_heat_potential
path: outputs/data/potentials/Sewage_heat_potential.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
heat capacity of total sewage in a zone |
|
heat extracted from sewage flows |
|
Inlet temperature of the sweage heapump |
|
Inlet temperature of sewage flows |
|
Outlet temperature of the sewage heatpump |
|
Outlet temperature of sewage flows |
|
Average temperature of sewage flows |
get_thermal_demand_csv_file
path: outputs/data/thermal-network/DH__thermal_demand_per_building_W.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal demand for building B01 at each simulation time step |
get_thermal_network_edge_list_file
path: outputs/data/thermal-network/DH__metadata_edges.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Internal pipe diameter for the nominal diameter |
|
Length of each pipe in the network |
|
Unique network pipe ID. |
|
Nominal pipe diameter (e.g. DN100 refers to pipes of approx. 100 mm in diameter) |
|
Material of the pipes |
get_thermal_network_edge_node_matrix_file
path: outputs/data/thermal-network/{network_type}__EdgeNode.csv
The following file is used by these scripts: thermal_network
Variable |
Description |
---|---|
|
Names of the nodes in the network |
|
Indicates the direction of flow of PIPE0 with respect to each node NODEn: if equal to PIPE0 and NODEn are not connected / if equal to 1 PIPE0 enters NODEn / if equal to -1 PIPE0 leaves NODEn |
get_thermal_network_layout_massflow_edges_file
path: outputs/data/thermal-network/DH__massflow_edges_kgs.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Mass flow rate in pipe PIPE0 at each time step |
get_thermal_network_layout_massflow_nodes_file
path: outputs/data/thermal-network/DH__massflow_nodes_kgs.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Mass flow rate in node NODE0 at each time step |
get_thermal_network_node_types_csv_file
path: outputs/data/thermal-network/DH__metadata_nodes.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Unique building ID. It must start with a letter. |
|
Unique network node ID. |
|
Type of node: “PLANT” / “CONSUMER” / “NONE” (if it is neither) |
get_thermal_network_plant_heat_requirement_file
path: outputs/data/thermal-network/DH__plant_thermal_load_kW.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Thermal load supplied by the plant at each time step |
get_thermal_network_pressure_losses_edges_file
path: outputs/data/thermal-network/DH__pressure_losses_edges_kW.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Pressure losses at pipe PIPE0 at each time step |
get_thermal_network_substation_ploss_file
path: outputs/data/thermal-network/DH__pumping_load_due_to_substations_kW.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Pumping load at building substation B01 for each timestep |
get_thermal_network_velocity_edges_file
path: outputs/data/thermal-network/DH__velocity_edges_mpers.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Flow velocity of heating/cooling medium in pipe PIPE0 |
get_total_demand
path: outputs/data/demand/Total_demand.csv
The following file is used by these scripts: decentralized
, emissions
, network_layout
, system_costs
, optimization
, sewage_potential
, thermal_network
Variable |
Description |
---|---|
|
Conditioned floor area (heated/cooled) |
|
Occupied floor area (heated/cooled) |
|
Roof area |
|
Nominal Coal requirement for space heating supply |
|
Coal requirement for space heating supply |
|
Nominal Coal requirement for hotwater supply |
|
Coal requirement for hotwater supply |
|
Nominal district cooling for final data center cooling demand |
|
District cooling for data center cooling demand |
|
Nominal district cooling for refrigeration demand |
|
District cooling for refrigeration demand |
|
Nominal district cooling for space cooling demand |
|
Energy consumption of space cooling system (if supplied by District Cooling), DC_cs = Qcs_sys / eff_cs |
|
Nominal energy requirement by district heating (space heating supply) |
|
Energy requirement by district heating (space heating supply) |
|
Nominal Energy requirement by district heating (hotwater supply) |
|
Energy requirement by district heating (hotwater supply) |
|
Nominal Data centre cooling specific electricity consumption. |
|
Electricity consumption due to data center cooling |
|
Nominal Refrigeration system electricity consumption. |
|
Electricity consumption due to refrigeration |
|
Nominal Cooling system electricity consumption. |
|
Energy consumption of cooling system (if supplied by electricity grid), E_cs = Qcs_sys / eff_cs |
|
Nominal Heating system electricity consumption. |
|
Electricity consumption due to space heating |
|
Nominal end-use electricity demand |
|
End-use total electricity consumption, E_sys = Eve + Ea + El + Edata + Epro + Eaux + Ev |
|
Nominal Domestic hot water electricity consumption. |
|
Electricity consumption due to hot water |
|
Nominal end-use electricity for appliances |
|
End-use electricity for appliances |
|
Nominal Total net electricity for all sources and sinks. |
|
End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W |
|
Nominal Auxiliary electricity consumption. |
|
End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux |
|
Nominal Data centre electricity consumption. |
|
Electricity consumption for data centers |
|
Nominal end-use electricity for lights |
|
End-use electricity for lights |
|
Nominal Industrial processes electricity consumption. |
|
Electricity supplied to industrial processes |
|
Nominal end-use electricity for electric vehicles |
|
End-use electricity for electric vehicles |
|
Nominal end-use electricity for ventilation |
|
End-use electricity for ventilation |
|
Gross floor area |
|
Nominal Grid electricity consumption |
|
Nominal grid electricity requirements for appliances |
|
Grid electricity requirements for appliances |
|
Nominal grid electricity requirements for auxiliary loads |
|
Grid electricity requirements for auxiliary loads |
|
Nominal grid electricity requirements for servers cooling |
|
Grid electricity requirements for servers cooling |
|
Nominal grid electricity requirements for refrigeration |
|
Grid electricity requirements for refrigeration |
|
Nominal grid electricity requirements for space cooling |
|
Grid electricity requirements for space cooling |
|
Nominal grid electricity requirements for servers |
|
Grid electricity requirements for servers |
|
Nominal grid electricity requirements for space heating |
|
Grid electricity requirements for space heating |
|
Nominal grid electricity consumption for lights |
|
Grid electricity requirements for lights |
|
Grid electricity consumption, GRID_a + GRID_l + GRID_v + GRID_ve + GRID_data + GRID_pro + GRID_aux + GRID_ww + GRID_cs + GRID_hs + GRID_cdata + GRID_cre |
|
Nominal grid electricity requirements for industrial processes |
|
Grid electricity requirements for industrial processes |
|
Nominal grid electricity consumption for electric vehicles |
|
Grid electricity requirements for electric vehicles |
|
Nominal grid electricity consumption for ventilation |
|
Grid electricity requirements for ventilation |
|
Nominal grid electricity requirements for hot water supply |
|
Grid electricity requirements for hot water supply |
|
Unique building ID. It must start with a letter. |
|
Nominal NG requirement for space heating supply |
|
NG requirement for space heating supply |
|
Nominal NG requirement for hotwater supply |
|
NG requirement for hotwater supply |
|
Nominal OIL requirement for space heating supply |
|
OIL requirement for space heating supply |
|
Nominal OIL requirement for hotwater supply |
|
OIL requirement for hotwater supply |
|
Nominal occupancy |
|
Nominal PV electricity consumption |
|
PV electricity consumption |
|
Nominal Total system cooling demand. |
|
Total energy demand for cooling, QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys |
|
Nominal Data centre cooling demand. |
|
Data centre cooling demand |
|
Nominal end-use data center cooling demand |
|
End-use data center cooling demand |
|
Nominal process cooling demand. |
|
Yearly processes cooling demand. |
|
Nominal Refrigeration cooling demand. |
|
Refrigeration cooling demand for the system |
|
|
|
End-use refrigeration demand |
|
Nominal Total cooling demand. |
|
Nominal Cooling distribution losses. |
|
Cooling distribution losses |
|
Nominal Cooling emission losses. |
|
Cooling emission losses |
|
Nominal AHU latent cooling demand. |
|
AHU latent cooling demand |
|
Nominal ARU latent cooling demand. |
|
ARU latent cooling demand |
|
Nominal System latent cooling demand. |
|
Latent cooling demand |
|
Total cooling demand |
|
Nominal AHU system cooling demand. |
|
AHU system cooling demand |
|
Nominal ARU system cooling demand. |
|
ARU system cooling demand |
|
Nominal SCU system cooling demand. |
|
SCU system cooling demand |
|
Nominal Sensible system cooling demand. |
|
Sensible system cooling demand |
|
Nominal end-use space cooling demand |
|
Nominal AHU system cooling demand. |
|
AHU system cooling demand |
|
Nominal ARU system cooling demand. |
|
ARU system cooling demand |
|
End-use space cooling demand, Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls |
|
Nominal SCU system cooling demand. |
|
SCU system cooling demand |
|
Nominal total building heating demand. |
|
Total energy demand for heating |
|
Nominal process heating demand. |
|
Yearly processes heating demand. |
|
Nominal Total heating demand. |
|
Nominal Heating system distribution losses. |
|
Heating system distribution losses |
|
Nominal Heating emission losses. |
|
Heating system emission losses |
|
Nominal AHU latent heating demand. |
|
AHU latent heating demand |
|
Nominal ARU latent heating demand. |
|
ARU latent heating demand |
|
Nominal System latent heating demand. |
|
System latent heating demand |
|
Total heating demand |
|
Nominal AHU sensible heating demand. |
|
Sensible heating demand in AHU |
|
ARU sensible heating demand |
|
ARU sensible heating demand |
|
Nominal SHU sensible heating demand. |
|
SHU sensible heating demand |
|
Nominal HVAC systems sensible heating demand. |
|
Sensible heating demand |
|
Nominal end-use space heating demand |
|
Nominal AHU sensible heating demand. |
|
AHU system heating demand |
|
Nominal ARU sensible heating demand. |
|
ARU sensible heating demand |
|
End-use space heating demand, Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls |
|
Nominal SHU sensible heating demand. |
|
SHU sensible heating demand |
|
Nominal DHW heating demand. |
|
DHW heating demand |
|
Nominal end-use hotwater demand |
|
End-use hotwater demand |
|
Nominal solar thermal energy requirement for space heating supply |
|
Solar thermal energy requirement for space heating supply |
|
Nominal solar thermal energy requirement for hotwater supply |
|
Solar thermal energy requirement for hotwater supply |
|
Nominal WOOD requirement for space heating supply |
|
WOOD requirement for space heating supply |
|
Nominal WOOD requirement for hotwater supply |
|
WOOD requirement for hotwater supply |
get_water_body_potential
path: outputs/data/potentials/Water_body_potential.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
thermal potential from water body |
|
average temperature of the water body |
get_weather_file
path: inputs/weather/weather.epw
The following file is used by these scripts: decentralized
, demand
, optimization
, photovoltaic
, photovoltaic_thermal
, radiation
, schedule_maker
, shallow_geothermal_potential
, solar_collector
, thermal_network
Variable |
Description |
---|---|
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
|
TODO |
PV_metadata_results
path: outputs/data/potentials/solar/B001_PV_sensors.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
The area of the building surface covered by one solar panel |
|
Surface area. |
|
Spacing between solar arrays. |
|
Tilt angle of the installed solar panels |
|
Unique building ID. It must start with a letter. |
|
Category according to the tilt angle of the panel |
|
Category according to the annual radiation on the panel surface |
|
Category according to the surface azimuth of the panel |
|
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
|
Orientation of the surface (north/east/south/west/top) |
|
Unique surface ID for each building exterior surface. |
|
Unique surface ID for each building exterior surface. |
|
Azimuth angle of the panel surface e.g. south facing = 180 deg |
|
Tilt angle of roof or walls |
|
Total radiatiative potential of a given surfaces area. |
|
Surface typology. |
|
Concatenated surface type and orientation. |
|
Describes the position of the x vector. |
|
Directional scalar of the x vector. |
|
Describes the position of the y vector. |
|
Directional scalar of the y vector. |
|
Describes the position of the z vector. |
|
Directional scalar of the z vector. |
PV_results
path: outputs/data/potentials/solar/B001_PV.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Date and time in hourly steps. |
|
Total electricity generated by the collector. |
|
Electricity production from photovoltaic panels on roof tops |
|
Collector surface area on roof tops. |
|
Electricity production from photovoltaic panels on east facades |
|
Collector surface area on east facades. |
|
Electricity production from photovoltaic panels on north facades |
|
Collector surface area on north facades. |
|
Electricity production from photovoltaic panels on south facades |
|
Collector surface area on south facades. |
|
Electricity production from photovoltaic panels on west facades |
|
West facing wall collector surface area. |
|
Total radiatiative potential. |
PV_total_buildings
path: outputs/data/potentials/solar/PV_total_buildings.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Total electricity generated by the collector. |
|
Unique building ID. It must start with a letter. |
|
Electricity production from photovoltaic panels on roof tops |
|
Collector surface area on roof tops. |
|
Electricity production from photovoltaic panels on east facades |
|
Collector surface area on east facades. |
|
Electricity production from photovoltaic panels on north facades |
|
Collector surface area on north facades. |
|
Electricity production from photovoltaic panels on south facades |
|
Collector surface area on south facades. |
|
Electricity production from photovoltaic panels on west facades |
|
West facing wall collector surface area. |
|
Total radiatiative potential. |
PV_totals
path: outputs/data/potentials/solar/PV_total.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Date and time in hourly steps. |
|
Total electricity generated by the collector. |
|
Electricity production from photovoltaic panels on roof tops |
|
Collector surface area on roof tops. |
|
Electricity production from photovoltaic panels on east facades |
|
Collector surface area on east facades. |
|
Electricity production from photovoltaic panels on north facades |
|
Collector surface area on north facades. |
|
Electricity production from photovoltaic panels on south facades |
|
Collector surface area on south facades. |
|
Electricity production from photovoltaic panels on west facades |
|
West facing wall collector surface area. |
|
Total radiatiative potential. |
PVT_metadata_results
path: outputs/data/potentials/solar/B001_PVT_sensors.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
The area of the building surface covered by one solar panel |
|
Surface area. |
|
Spacing between solar arrays. |
|
Tilt angle of the installed solar panels |
|
Unique building ID. It must start with a letter. |
|
Category according to the tilt angle of the panel |
|
Category according to the annual radiation on the panel surface |
|
Category according to the surface azimuth of the panel |
|
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
|
Orientation of the surface (north/east/south/west/top) |
|
Unique surface ID for each building exterior surface. |
|
Unique surface ID for each building exterior surface. |
|
Azimuth angle of the panel surface e.g. south facing = 180 deg |
|
Tilt angle of roof or walls |
|
Total radiatiative potential of a given surfaces area. |
|
Surface typology. |
|
Concatenated surface type and orientation. |
|
Describes the position of the x vector. |
|
Directional scalar of the x vector. |
|
Describes the position of the y vector. |
|
Directional scalar of the y vector. |
|
Describes the position of the z vector. |
|
Directional scalar of the z vector. |
PVT_results
path: outputs/data/potentials/solar/B001_PVT.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Date and time in hourly steps. |
|
Total electricity generated by the collector. |
|
Auxiliary electricity consumed by the collector. |
|
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
|
Electricity production from photovoltaic-thermal panels on roof tops |
|
Collector surface area on roof tops. |
|
Heat production from photovoltaic-thermal panels on roof tops |
|
Electricity production from photovoltaic-thermal panels on east facades |
|
Collector surface area on east facades. |
|
Heat production from photovoltaic-thermal panels on east facades |
|
Electricity production from photovoltaic-thermal panels on north facades |
|
Collector surface area on north facades. |
|
Heat production from photovoltaic-thermal panels on north facades |
|
Electricity production from photovoltaic-thermal panels on south facades |
|
Collector surface area on south facades. |
|
Heat production from photovoltaic-thermal panels on south facades |
|
Electricity production from photovoltaic-thermal panels on west facades |
|
West facing wall collector surface area. |
|
Heat production from photovoltaic-thermal panels on west facades |
|
Total heat generated by the collector. |
|
Collector heat loss. |
|
Total radiatiative potential. |
|
Collector hot water return temperature. |
|
Collector heating supply temperature. |
PVT_total_buildings
path: outputs/data/potentials/solar/PVT_total_buildings.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Total electricity generated by the collector. |
|
Auxiliary electricity consumed by the collector. |
|
Unique building ID. |
|
Electricity production from photovoltaic-thermal panels on roof tops |
|
Collector surface area on roof tops. |
|
Heat production from photovoltaic-thermal panels on roof tops |
|
Electricity production from photovoltaic-thermal panels on east facades |
|
Collector surface area on east facades. |
|
Heat production from photovoltaic-thermal panels on east facades |
|
Electricity production from photovoltaic-thermal panels on north facades |
|
Collector surface area on north facades. |
|
Heat production from photovoltaic-thermal panels on north facades |
|
Electricity production from photovoltaic-thermal panels on south facades |
|
Collector surface area on south facades. |
|
Heat production from photovoltaic-thermal panels on south facades |
|
Electricity production from photovoltaic-thermal panels on west facades |
|
West facing wall collector surface area. |
|
Heat production from photovoltaic-thermal panels on west facades |
|
Total heat generated by the collector. |
|
Collector heat loss. |
|
Total radiatiative potential. |
PVT_totals
path: outputs/data/potentials/solar/PVT_total.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Date and time in hourly steps. |
|
Total electricity generated by the collector. |
|
Auxiliary electricity consumed by the collector. |
|
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
|
Electricity production from photovoltaic-thermal panels on roof tops |
|
Collector surface area on roof tops. |
|
Heat production from photovoltaic-thermal panels on roof tops |
|
Electricity production from photovoltaic-thermal panels on east facades |
|
Collector surface area on east facades. |
|
Heat production from photovoltaic-thermal panels on east facades |
|
Electricity production from photovoltaic-thermal panels on north facades |
|
Collector surface area on north facades. |
|
Heat production from photovoltaic-thermal panels on north facades |
|
Electricity production from photovoltaic-thermal panels on south facades |
|
Collector surface area on south facades. |
|
Heat production from photovoltaic-thermal panels on south facades |
|
Electricity production from photovoltaic-thermal panels on west facades |
|
West facing wall collector surface area. |
|
Heat production from photovoltaic-thermal panels on west facades |
|
Total heat generated by the collector. |
|
Collector heat loss. |
|
Total radiatiative potential. |
|
Collector heating supply temperature. |
|
Collector heating supply temperature. |
SC_metadata_results
path: outputs/data/potentials/solar/B001_SC_ET_sensors.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
The area of the building surface covered by one solar panel |
|
Surface area. |
|
Spacing between solar arrays. |
|
Tilt angle of the installed solar panels |
|
Unique building ID. It must start with a letter. |
|
Category according to the tilt angle of the panel |
|
Category according to the annual radiation on the panel surface |
|
Category according to the surface azimuth of the panel |
|
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
|
Orientation of the surface (north/east/south/west/top) |
|
Unique surface ID for each building exterior surface. |
|
Unique surface ID for each building exterior surface. |
|
Azimuth angle of the panel surface e.g. south facing = 180 deg |
|
Tilt angle of roof or walls |
|
Total radiatiative potential of a given surfaces area. |
|
Surface typology. |
|
Concatenated surface type and orientation. |
|
Describes the position of the x vector. |
|
Directional scalar of the x vector. |
|
Describes the position of the y vector. |
|
Directional scalar of the y vector. |
|
Describes the position of the z vector. |
|
Directional scalar of the z vector. |
SC_results
path: outputs/data/potentials/solar/B001_SC_ET.csv
The following file is used by these scripts: decentralized
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Date and time in hourly steps. |
|
Auxiliary electricity consumed by the collector. |
|
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
|
Total heat generated by the collector. |
|
Collector heat loss. |
|
Total radiatiative potential. |
|
Collector surface area on roof tops. |
|
Heat production from solar collectors on roof tops |
|
Collector surface area on east facades. |
|
Heat production from solar collectors on east facades |
|
Collector surface area on north facades. |
|
Heat production from solar collectors on north facades |
|
Collector surface area on south facades. |
|
Heat production from solar collectors on south facades |
|
Collector surface area on west facades. |
|
Heat production from solar collectors on west facades |
|
Collector hot water return temperature. |
|
Collector hot water supply temperature. |
SC_total_buildings
path: outputs/data/potentials/solar/SC_ET_total_buildings.csv
The following file is used by these scripts:
Variable |
Description |
---|---|
|
Total area of investigated collector. |
|
Auxiliary electricity consumed by the collector. |
|
Unique building ID. |
|
Total heat generated by the collector. |
|
Collector heat loss. |
|
Total radiatiative potential. |
|
Roof top collector surface area. |
|
Heat production from solar collectors on roof tops |
|
East facing wall collector surface area. |
|
Heat production from solar collectors on east facades |
|
North facing wall collector surface area. |
|
Heat production from solar collectors on west facades |
|
South facing wall collector surface area. |
|
Heat production from solar collectors on south facades |
|
West facing wall collector surface area. |
|
Heat production from solar collectors on west facades |
SC_totals
path: outputs/data/potentials/solar/SC_FP_total.csv
The following file is used by these scripts: optimization
Variable |
Description |
---|---|
|
Collector surface area on south facades. |
|
Date and time in hourly steps. |
|
Auxiliary electricity consumed by the collector. |
|
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
|
Total heat generated by the collector. |
|
Collector heat loss. |
|
Total radiatiative potential. |
|
Collector surface area on roof tops. |
|
Heat production from solar collectors on roof tops |
|
Collector surface area on east facades. |
|
Heat production from solar collectors on east facades |
|
Collector surface area on north facades. |
|
Heat production from solar collectors on north facades |
|
Collector surface area on south facades. |
|
Heat production from solar collectors on south facades |
|
Collector surface area on west facades. |
|
Heat production from solar collectors on west facades |
|
Collector hot water return temperature. |
|
Collector hot water supply temperature. |