get_building_typology¶
path: inputs/building-properties/typology.dbf
The following file is used by these scripts: archetypes_mapper
, demand
, emissions
Variable | Description |
---|---|
1ST_USE |
First (Main) Use type of the building |
1ST_USE_R |
Fraction of gross floor area for first Use Type |
2ND_USE |
Second Use type of the building |
2ND_USE_R |
Fraction of gross floor area for second Use Type |
3RD_USE |
Third Use type of the building |
3RD_USE_R |
Fraction of gross floor area for third Use Type |
Name |
Unique building ID. It must start with a letter. |
REFERENCE |
Reference to data (if any) |
STANDARD |
Construction Standard (relates to “code” in Supply Assemblies) |
YEAR |
Construction year |
get_costs_operation_file¶
path: outputs/data/costs/operation_costs.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Aocc_m2 |
Occupied floor area (heated/cooled) |
Capex_a_sys_building_scale_USD |
Annualized capital expenditures of building-scale systems |
Capex_a_sys_district_scale_USD |
Annualized capital expenditures of district-scale systems |
COAL_hs_cost_m2yr |
Operation costs of coal due to space heating per unit conditioned floor area |
COAL_hs_cost_yr |
Operation costs of coal due to space heating |
COAL_ww_cost_m2yr |
Operation costs of coal due to hotwater per unit conditioned floor area |
COAL_ww_cost_yr |
Operation costs of coal due to hotwater |
DC_cdata_cost_m2yr |
Operation costs of district cooling due to data center cooling per unit conditioned floor area |
DC_cdata_cost_yr |
Operation costs of district cooling due to data center cooling |
DC_cre_cost_m2yr |
Operation costs of district cooling due to cool room refrigeration per unit conditioned floor area |
DC_cre_cost_yr |
Operation costs of district cooling due to cool room refrigeration |
DC_cs_cost_m2yr |
Operation costs of district cooling due to space cooling per unit conditioned floor area |
DC_cs_cost_yr |
Operation costs of district cooling due to space cooling |
DH_hs_cost_m2yr |
Operation costs of district heating due to space heating per unit conditioned floor area |
DH_hs_cost_yr |
Operation costs of district heating due to space heating |
DH_ww_cost_m2yr |
Operation costs of district heating due to domestic hot water per unit conditioned floor area |
DH_ww_cost_yr |
Operation costs of district heating due to domestic hot water |
GRID_cost_m2yr |
Operation costs due to electricity supply from the grid per unit conditioned floor area |
GRID_cost_yr |
Operation costs due to electricity supply from the grid |
Name |
Unique building ID. It must start with a letter. |
NG_hs_cost_m2yr |
Operation costs of natural gas due to space heating per unit conditioned floor area |
NG_hs_cost_yr |
Operation costs of natural gas due to space heating |
NG_ww_cost_m2yr |
Operation costs of natural gas due to domestic hot water per unit conditioned floor area |
NG_ww_cost_yr |
Operation costs of natural gas due to domestic hot water |
OIL_hs_cost_m2yr |
Operation costs of oil due to space heating per unit conditioned floor area |
OIL_hs_cost_yr |
Operation costs of oil due to space heating |
OIL_ww_cost_m2yr |
Operation costs of oil due to domestic hot water per unit conditioned floor area |
OIL_ww_cost_yr |
Operation costs of oil due to domestic hot water |
Opex_a_sys_building_scale_USD |
Annual operational expenditures of building-scale systems |
Opex_a_sys_district_scale_USD |
Annual operational expenditures of district-scale systems |
PV_cost_m2yr |
Operation costs due to electricity supply from PV per unit conditioned floor area |
PV_cost_yr |
Operation costs due to electricity supply from PV |
SOLAR_hs_cost_m2yr |
Operation costs due to solar collectors for space heating per unit conditioned floor area |
SOLAR_hs_cost_yr |
Operation costs due to solar collectors for space heating |
SOLAR_ww_cost_m2yr |
Operation costs due to solar collectors for domestic hot water per unit conditioned floor area |
SOLAR_ww_cost_yr |
Operation costs due to solar collectors for domestic hot water |
WOOD_hs_cost_m2yr |
Operation costs of wood due to space heating per unit conditioned floor area |
WOOD_hs_cost_yr |
Operation costs of wood due to space heating |
WOOD_ww_cost_m2yr |
Operation costs of wood due to domestic hot water per unit conditioned floor area |
WOOD_ww_cost_yr |
Operation costs of wood due to domestic hot water |
get_demand_results_file¶
path: outputs/data/demand/B001.csv
The following file is used by these scripts: decentralized
, optimization
, sewage_potential
, thermal_network
Variable | Description |
---|---|
COAL_hs_kWh |
Coal requirement for space heating supply |
COAL_ww_kWh |
Coal requirement for hotwater supply |
DATE |
Time stamp for each day of the year ascending in hour intervals. |
DC_cdata_kWh |
District cooling for data center cooling demand |
DC_cre_kWh |
District cooling for refrigeration demand |
DC_cs_kWh |
Energy consumption of space cooling system (if supplied by District Cooling), DC_cs = Qcs_sys / eff_cs |
DH_hs_kWh |
Energy requirement by district heating (space heating supply) |
DH_ww_kWh |
Energy requirement by district heating (hotwater supply) |
E_cdata_kWh |
Data centre cooling specific electricity consumption. |
E_cre_kWh |
Refrigeration system electricity consumption. |
E_cs_kWh |
Energy consumption of cooling system (if supplied by electricity grid), E_cs = Qcs_sys / eff_cs |
E_hs_kWh |
Heating system electricity consumption. |
E_sys_kWh |
End-use total electricity consumption = Ea + El + Edata + Epro + Eaux + Ev + Eve |
E_ww_kWh |
Hot water system electricity consumption. |
Ea_kWh |
End-use electricity for appliances |
Eal_kWh |
End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W |
Eaux_kWh |
End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux |
Edata_kWh |
End-use data centre electricity consumption. |
El_kWh |
End-use electricity for lights |
Epro_kWh |
End-use electricity consumption for industrial processes. |
Ev_kWh |
End-use electricity for electric vehicles |
Eve_kWh |
End-use electricity for ventilation |
GRID_a_kWh |
Grid electricity consumption for appliances |
GRID_aux_kWh |
Grid electricity consumption for auxiliary loads |
GRID_cdata_kWh |
Grid electricity consumption for servers cooling |
GRID_cre_kWh |
Grid electricity consumption for refrigeration |
GRID_cs_kWh |
Grid electricity consumption for space cooling |
GRID_data_kWh |
Grid electricity consumption for servers |
GRID_hs_kWh |
Grid electricity consumption for space heating |
GRID_kWh |
Grid total electricity consumption, GRID_a + GRID_l + GRID_v + GRID_ve + GRID_data + GRID_pro + GRID_aux + GRID_ww + GRID_cs + GRID_hs + GRID_cdata + GRID_cre |
GRID_l_kWh |
Grid electricity consumption for lighting |
GRID_pro_kWh |
Grid electricity consumption for industrial processes |
GRID_ve_kWh |
Grid electricity consumption for ventilation |
GRID_ww_kWh |
Grid electricity consumption for hot water supply |
I_rad_kWh |
Radiative heat loss |
I_sol_and_I_rad_kWh |
Net radiative heat gain |
I_sol_kWh |
Solar heat gain |
mcpcdata_sys_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of the chilled water delivered to data centre. |
mcpcre_sys_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to refrigeration. |
mcpcs_sys_ahu_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to air handling units (space cooling). |
mcpcs_sys_aru_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to air recirculation units (space cooling). |
mcpcs_sys_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to space cooling. |
mcpcs_sys_scu_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to sensible cooling units (space cooling). |
mcphs_sys_ahu_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to air handling units (space heating). |
mcphs_sys_aru_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to air recirculation units (space heating). |
mcphs_sys_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to space heating. |
mcphs_sys_shu_kWperC |
Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to sensible heating units (space heating). |
mcptw_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of the fresh water |
mcpww_sys_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of domestic hot water |
Name |
Unique building ID. It must start with a letter. |
NG_hs_kWh |
NG requirement for space heating supply |
NG_ww_kWh |
NG requirement for hotwater supply |
OIL_hs_kWh |
OIL requirement for space heating supply |
OIL_ww_kWh |
OIL requirement for hotwater supply |
people |
Predicted occupancy: number of people in building |
PV_kWh |
PV electricity consumption |
Q_gain_lat_peop_kWh |
Latent heat gain from people |
Q_gain_sen_app_kWh |
Sensible heat gain from appliances |
Q_gain_sen_base_kWh |
Sensible heat gain from transmission through the base |
Q_gain_sen_data_kWh |
Sensible heat gain from data centres |
Q_gain_sen_light_kWh |
Sensible heat gain from lighting |
Q_gain_sen_peop_kWh |
Sensible heat gain from people |
Q_gain_sen_pro_kWh |
Sensible heat gain from industrial processes. |
Q_gain_sen_roof_kWh |
Sensible heat gain from transmission through the roof |
Q_gain_sen_vent_kWh |
Sensible heat gain from ventilation and infiltration |
Q_gain_sen_wall_kWh |
Sensible heat gain from transmission through the walls |
Q_gain_sen_wind_kWh |
Sensible heat gain from transmission through the windows |
Q_loss_sen_ref_kWh |
Sensible heat loss from refrigeration systems |
QC_sys_kWh |
Total energy demand for cooling, QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys |
Qcdata_kWh |
Data centre space cooling demand |
Qcdata_sys_kWh |
End-use data center cooling demand |
Qcpro_sys_kWh |
Process cooling demand |
Qcre_kWh |
Refrigeration space cooling demand |
Qcre_sys_kWh |
End-use refrigeration demand |
Qcs_dis_ls_kWh |
Cooling system distribution losses |
Qcs_em_ls_kWh |
Cooling system emission losses |
Qcs_kWh |
Specific cooling demand |
Qcs_lat_ahu_kWh |
AHU latent cooling demand |
Qcs_lat_aru_kWh |
ARU latent cooling demand |
Qcs_lat_sys_kWh |
Total latent cooling demand for all systems |
Qcs_sen_ahu_kWh |
AHU sensible cooling demand |
Qcs_sen_aru_kWh |
ARU sensible cooling demand |
Qcs_sen_scu_kWh |
SHU sensible cooling demand |
Qcs_sen_sys_kWh |
Total sensible cooling demand for all systems |
Qcs_sys_ahu_kWh |
AHU system cooling demand |
Qcs_sys_aru_kWh |
ARU system cooling demand |
Qcs_sys_kWh |
End-use space cooling demand, Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls |
Qcs_sys_scu_kWh |
SCU system cooling demand |
QH_sys_kWh |
Total energy demand for heating, QH_sys = Qww_sys + Qhs_sys + Qhpro_sys |
Qhpro_sys_kWh |
Process heating demand |
Qhs_dis_ls_kWh |
Heating system distribution losses |
Qhs_em_ls_kWh |
Heating system emission losses |
Qhs_kWh |
Sensible heating system demand |
Qhs_lat_ahu_kWh |
AHU latent heating demand |
Qhs_lat_aru_kWh |
ARU latent heating demand |
Qhs_lat_sys_kWh |
Total latent heating demand for all systems |
Qhs_sen_ahu_kWh |
AHU sensible heating demand |
Qhs_sen_aru_kWh |
ARU sensible heating demand |
Qhs_sen_shu_kWh |
SHU sensible heating demand |
Qhs_sen_sys_kWh |
Total sensible heating demand |
Qhs_sys_ahu_kWh |
Space heating demand in AHU |
Qhs_sys_aru_kWh |
Space heating demand in ARU |
Qhs_sys_kWh |
End-use space heating demand, Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls |
Qhs_sys_shu_kWh |
SHU system heating demand |
Qww_kWh |
DHW specific heating demand |
Qww_sys_kWh |
End-use hotwater demand |
SOLAR_hs_kWh |
Solar thermal energy requirement for space heating supply |
SOLAR_ww_kWh |
Solar thermal energy requirement for hotwater supply |
T_ext_C |
Outdoor temperature |
T_int_C |
Indoor temperature |
Tcdata_sys_re_C |
Cooling supply temperature of the data centre |
Tcdata_sys_sup_C |
Cooling return temperature of the data centre |
Tcre_sys_re_C |
Cooling return temperature of the refrigeration system. |
Tcre_sys_sup_C |
Cooling supply temperature of the refrigeration system. |
Tcs_sys_re_ahu_C |
Return temperature cooling system |
Tcs_sys_re_aru_C |
Return temperature cooling system |
Tcs_sys_re_C |
System cooling return temperature. |
Tcs_sys_re_scu_C |
Return temperature cooling system |
Tcs_sys_sup_ahu_C |
Supply temperature cooling system |
Tcs_sys_sup_aru_C |
Supply temperature cooling system |
Tcs_sys_sup_C |
System cooling supply temperature. |
Tcs_sys_sup_scu_C |
Supply temperature cooling system |
theta_o_C |
Operative temperature in building (RC-model) used for comfort plotting |
Ths_sys_re_ahu_C |
Return temperature heating system |
Ths_sys_re_aru_C |
Return temperature heating system |
Ths_sys_re_C |
Heating system return temperature. |
Ths_sys_re_shu_C |
Return temperature heating system |
Ths_sys_sup_ahu_C |
Supply temperature heating system |
Ths_sys_sup_aru_C |
Supply temperature heating system |
Ths_sys_sup_C |
Heating system supply temperature. |
Ths_sys_sup_shu_C |
Supply temperature heating system |
Tww_sys_re_C |
Return temperature hotwater system |
Tww_sys_sup_C |
Supply temperature hotwater system |
WOOD_hs_kWh |
WOOD requirement for space heating supply |
WOOD_ww_kWh |
WOOD requirement for hotwater supply |
x_int |
Internal mass fraction of humidity (water/dry air) |
get_geothermal_potential¶
path: outputs/data/potentials/Shallow_geothermal_potential.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Area_avail_m2 |
areas available to install ground source heat pumps |
QGHP_kW |
geothermal heat potential |
Ts_C |
ground temperature |
get_lca_embodied¶
path: outputs/data/emissions/Total_LCA_embodied.csv
The following file is used by these scripts:
Variable | Description |
---|---|
GFA_m2 |
Gross floor area |
GHG_sys_embodied_kgCO2m2 |
Embodied emissions per conditioned floor area due to building construction and decomissioning |
GHG_sys_embodied_tonCO2 |
Embodied emissions due to building construction and decomissioning |
Name |
Unique building ID. It must start with a letter. |
get_lca_mobility¶
path: outputs/data/emissions/Total_LCA_mobility.csv
The following file is used by these scripts:
Variable | Description |
---|---|
GFA_m2 |
Gross floor area |
GHG_sys_mobility_kgCO2m2 |
Operational emissions per unit of conditioned floor area due to mobility |
GHG_sys_mobility_tonCO2 |
Operational emissions due to mobility |
Name |
Unique building ID. It must start with a letter. |
get_lca_operation¶
path: outputs/data/emissions/Total_LCA_operation.csv
The following file is used by these scripts:
Variable | Description |
---|---|
COAL_hs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the coal powererd heating system |
COAL_hs_ghg_ton |
Operational emissions of the coal powered heating system |
COAL_hs_nre_pen_GJ |
Operational primary energy demand (non-renewable) for coal powered heating system |
COAL_hs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the coal powered heating system |
COAL_ww_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the coal powered domestic hot water system |
COAL_ww_ghg_ton |
Operational emissions of the coal powered domestic hot water system |
COAL_ww_nre_pen_GJ |
Operational primary energy demand (non-renewable) for coal powered domestic hot water system |
COAL_ww_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the coal powered domestic hot water system |
DC_cdata_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the district cooling for the data center |
DC_cdata_ghg_ton |
Operational emissions of the district cooling for the data center |
DC_cdata_nre_pen_GJ |
Operational primary energy demand (non-renewable) for district cooling system for cool room refrigeration |
DC_cdata_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) for district cooling for cool room refrigeration |
DC_cre_ghg_kgm2 |
Operational emissions per unit of conditioned floor area for district cooling system for cool room refrigeration |
DC_cre_ghg_ton |
Operational emissions for district cooling system for cool room refrigeration |
DC_cre_nre_pen_GJ |
Operational primary energy demand (non-renewable) for district cooling system for cool room refrigeration |
DC_cre_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) for cool room refrigeration |
DC_cs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the district cooling |
DC_cs_ghg_ton |
Operational emissions of the district cooling |
DC_cs_nre_pen_GJ |
Operational primary energy demand (non-renewable) for district cooling system |
DC_cs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the district cooling |
DH_hs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the district heating system |
DH_hs_ghg_ton |
Operational emissions of the district heating system |
DH_hs_nre_pen_GJ |
Operational primary energy demand (non-renewable) for district heating system |
DH_hs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the district heating system |
DH_ww_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the district heating domestic hot water system |
DH_ww_ghg_ton |
Operational emissions of the district heating powered domestic hot water system |
DH_ww_nre_pen_GJ |
Operational primary energy demand (non-renewable) for district heating powered domestic hot water system |
DH_ww_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the district heating domestic hot water system |
GFA_m2 |
Gross floor area |
GHG_sys_kgCO2m2 |
Total operational emissions per unit of conditioned floor area |
GHG_sys_tonCO2 |
Total operational emissions |
GRID_ghg_kgm2 |
Operational emissions per unit of conditioned floor area from grid electricity |
GRID_ghg_ton |
Operational emissions of the electrictiy from the grid |
GRID_nre_pen_GJ |
Operational primary energy demand (non-renewable) from the grid |
GRID_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) from grid electricity |
Name |
Unique building ID. It must start with a letter. |
NG_hs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the natural gas powered heating system |
NG_hs_ghg_ton |
Operational emissions of the natural gas powered heating system |
NG_hs_nre_pen_GJ |
Operational primary energy demand (non-renewable) for natural gas powered heating system |
NG_hs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the natural gas powered heating system |
NG_ww_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the gas powered domestic hot water system |
NG_ww_ghg_ton |
Operational emissions of the solar powered domestic hot water system |
NG_ww_nre_pen_GJ |
Operational primary energy demand (non-renewable) for natural gas powered domestic hot water system |
NG_ww_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the natural gas powered domestic hot water system |
OIL_hs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the oil powered heating system |
OIL_hs_ghg_ton |
Operational emissions of the oil powered heating system |
OIL_hs_nre_pen_GJ |
Operational primary energy demand (non-renewable) for oil powered heating system |
OIL_hs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the oil powered heating system |
OIL_ww_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the oil powered domestic hot water system |
OIL_ww_ghg_ton |
Operational emissions of the oil powered domestic hot water system |
OIL_ww_nre_pen_GJ |
Operational primary energy demand (non-renewable) for oil powered domestic hot water system |
OIL_ww_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the oil powered domestic hot water system |
PV_ghg_kgm2 |
Operational emissions per unit of conditioned floor area for PV-System |
PV_ghg_ton |
Operational emissions of the PV-System |
PV_nre_pen_GJ |
Operational primary energy demand (non-renewable) for PV-System |
PV_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) for PV System |
SOLAR_hs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the solar powered heating system |
SOLAR_hs_ghg_ton |
Operational emissions of the solar powered heating system |
SOLAR_hs_nre_pen_GJ |
Operational primary energy demand (non-renewable) of the solar powered heating system |
SOLAR_hs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the solar powered heating system |
SOLAR_ww_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the solar powered domestic hot water system |
SOLAR_ww_ghg_ton |
Operational emissions of the solar powered domestic hot water system |
SOLAR_ww_nre_pen_GJ |
Operational primary energy demand (non-renewable) for solar powered domestic hot water system |
SOLAR_ww_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the solar poweed domestic hot water system |
WOOD_hs_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the wood powered heating system |
WOOD_hs_ghg_ton |
Operational emissions of the wood powered heating system |
WOOD_hs_nre_pen_GJ |
Operational primary energy demand (non-renewable) for wood powered heating system |
WOOD_hs_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the wood powered heating system |
WOOD_ww_ghg_kgm2 |
Operational emissions per unit of conditioned floor area of the wood powered domestic hot water system |
WOOD_ww_ghg_ton |
Operational emissions of the wood powered domestic hot water system |
WOOD_ww_nre_pen_GJ |
Operational primary energy demand (non-renewable) for wood powered domestic hot water system |
WOOD_ww_nre_pen_MJm2 |
Operational primary energy demand per unit of conditioned floor area (non-renewable) of the wood powered domestic hot water system |
get_multi_criteria_analysis¶
path: outputs/data/multicriteria/gen_2_multi_criteria_analysis.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_sys_building_scale_USD |
Annualized Capital costs of building-scale systems |
Capex_a_sys_district_scale_USD |
Capital costs of district-scale systems |
Capex_a_sys_USD |
Capital costs of all systems |
Capex_total_sys_building_scale_USD |
Capital costs of building-scale systems |
Capex_total_sys_district_scale_USD |
Capital costs of district-scale systems |
Capex_total_sys_USD |
Capital costs of all systems |
generation |
Generation or iteration |
GHG_rank |
Rank for emissions |
GHG_sys_building_scale_tonCO2 |
Green house gas emissions of building-scale systems |
GHG_sys_district_scale_tonCO2 |
Green house gas emissions of building-scale systems |
GHG_sys_tonCO2 |
Green house gas emissions of all systems |
individual |
system number |
individual_name |
Name of system |
normalized_Capex_total |
normalization of CAPEX |
normalized_emissions |
normalization of GHG |
normalized_Opex |
Normalization of OPEX |
normalized_TAC |
normalization of TAC |
Opex_a_sys_building_scale_USD |
Operational costs of building-scale systems |
Opex_a_sys_district_scale_USD |
Operational costs of district-scale systems |
Opex_a_sys_USD |
Operational costs of all systems |
TAC_rank |
Rank of TAC |
TAC_sys_building_scale_USD |
Equivalent annual costs of building-scale systems |
TAC_sys_district_scale_USD |
Equivalent annual of district-scale systems |
TAC_sys_USD |
Equivalent annual costs of all systems |
user_MCDA |
Best system accoridng to user mult-criteria weights |
user_MCDA_rank |
Rank of Best system according to user mult-criteria weights |
get_network_energy_pumping_requirements_file¶
path: outputs/data/thermal-network/DH__plant_pumping_load_kW.csv
The following file is used by these scripts:
Variable | Description |
---|---|
pressure_loss_return_kW |
pumping electricity required to overcome pressure losses in the return network |
pressure_loss_substations_kW |
pumping electricity required to overcome pressure losses in the substations |
pressure_loss_supply_kW |
pumping electricity required to overcome pressure losses in the supply network |
pressure_loss_total_kW |
pumping electricity required to overcome pressure losses in the entire network |
get_network_layout_edges_shapefile¶
path: outputs/data/thermal-network/DH/edges.shp
The following file is used by these scripts: thermal_network
Variable | Description |
---|---|
geometry |
Geometry |
length_m |
lenth of this edge |
Name |
Unique network pipe ID. |
Pipe_DN |
Classifies nominal pipe diameters (DN) into typical bins. |
Type_mat |
Material type |
get_network_layout_nodes_shapefile¶
path: outputs/data/thermal-network/DH/nodes.shp
The following file is used by these scripts: thermal_network
Variable | Description |
---|---|
Building |
Unique building ID. e.g. “B01” |
geometry |
Geometry |
Name |
Unique node ID. e.g. “NODE1” |
Type |
Type of node. |
get_network_linear_pressure_drop_edges¶
path: outputs/data/thermal-network/DH__linear_pressure_drop_edges_Paperm.csv
The following file is used by these scripts:
Variable | Description |
---|---|
PIPE0 |
linear pressure drop in this pipe section |
get_network_linear_thermal_loss_edges_file¶
path: outputs/data/thermal-network/DH__linear_thermal_loss_edges_Wperm.csv
The following file is used by these scripts:
Variable | Description |
---|---|
PIPE0 |
linear thermal losses in thie pipe section |
get_network_pressure_at_nodes¶
path: outputs/data/thermal-network/DH__pressure_at_nodes_Pa.csv
The following file is used by these scripts:
Variable | Description |
---|---|
NODE0 |
pressure at this node |
get_network_temperature_plant¶
path: outputs/data/thermal-network/DH__temperature_plant_K.csv
The following file is used by these scripts:
Variable | Description |
---|---|
temperature_return_K |
Plant return temperature at each time step |
temperature_supply_K |
Plant supply temperature at each time step |
get_network_temperature_return_nodes_file¶
path: outputs/data/thermal-network/DH__temperature_return_nodes_K.csv
The following file is used by these scripts:
Variable | Description |
---|---|
NODE0 |
Return temperature at node NODE0 (outlet temperature of NODE0) at each time step |
get_network_temperature_supply_nodes_file¶
path: outputs/data/thermal-network/DH__temperature_supply_nodes_K.csv
The following file is used by these scripts:
Variable | Description |
---|---|
NODE0 |
Supply temperature at node NODE0 (inlet temperature of NODE0) at each time step |
get_network_thermal_loss_edges_file¶
path: outputs/data/thermal-network/DH__thermal_loss_edges_kW.csv
The following file is used by these scripts:
Variable | Description |
---|---|
PIPE0 |
Thermal losses along pipe PIPE0 at each time step |
get_network_total_pressure_drop_file¶
path: outputs/data/thermal-network/DH__plant_pumping_pressure_loss_Pa.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
pressure_loss_return_Pa |
Pressure losses in the return network at each time step |
pressure_loss_substations_Pa |
Pressure losses in all substations at each time step |
pressure_loss_supply_Pa |
Pressure losses in the supply network at each time step |
pressure_loss_total_Pa |
Total pressure losses in the entire thermal network at each time step |
get_network_total_thermal_loss_file¶
path: outputs/data/thermal-network/DH__total_thermal_loss_edges_kW.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
thermal_loss_return_kW |
Thermal losses in the supply network at each time step |
thermal_loss_supply_kW |
Thermal losses in the return network at each time step |
thermal_loss_total_kW |
Thermal losses in the entire thermal network at each time step |
get_nominal_edge_mass_flow_csv_file¶
path: outputs/data/thermal-network/Nominal_EdgeMassFlow_at_design_{network_type}__kgpers.csv
The following file is used by these scripts: thermal_network
Variable | Description |
---|---|
PIPE0 |
Mass flow rate in pipe PIPE0 at design operating conditions |
get_nominal_node_mass_flow_csv_file¶
path: outputs/data/thermal-network/Nominal_NodeMassFlow_at_design_{network_type}__kgpers.csv
The following file is used by these scripts: thermal_network
Variable | Description |
---|---|
NODE0 |
Mass flow rate in node NODE0 at design operating conditions |
get_optimization_building_scale_cooling_capacity¶
path: outputs/data/optimization/slave/gen_1/ind_0_building_scale_cooling_capacity.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capacity_ACH_SC_FP_cool_building_scale_W |
Thermal Capacity of Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
Capacity_ACHHT_FP_cool_building_scale_W |
Thermal Capacity of High-Temperature Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
Capacity_BaseVCC_AS_cool_building_scale_W |
Thermal Capacity of Base load Vapor Compression Chiller for Decentralized Building |
Capacity_DX_AS_cool_building_scale_W |
Thermal Capacity of Direct Expansion Air-Source for Decentralized Building |
Capacity_VCCHT_AS_cool_building_scale_W |
Thermal Capacity of High-Temperature Vapor Compression Chiller (Air-Source) for Decentralized Building |
Capaticy_ACH_SC_ET_cool_building_scale_W |
Thermal Capacity of Absorption Chiller and Solar Collector (Evacuated Tube)for Decentralized Building |
Name |
Unique building ID. It must start with a letter |
get_optimization_building_scale_heating_capacity¶
path: outputs/data/optimization/slave/gen_0/ind_1_building_scale_heating_capacity.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capacity_BaseBoiler_NG_heat_building_scale_W |
Thermal capacity of Base load boiler for Decentralized building |
Capacity_FC_NG_heat_building_scale_W |
Thermal capacity of Fuel Cell for Decentralized building |
Capacity_GS_HP_heat_building_scale_W |
Thermal capacity of ground-source heat pump for Decentralized building |
Name |
Unique building ID. It must start with a letter |
get_optimization_checkpoint¶
path: outputs/data/optimization/master/CheckPoint_1
The following file is used by these scripts:
Variable | Description |
---|---|
difference_generational_distances |
TODO |
generation |
TODO |
generational_distances |
TODO |
selected_population |
TODO |
tested_population |
TODO |
get_optimization_decentralized_folder_building_result_cooling¶
path: outputs/data/optimization/decentralized/{building}_{configuration}_cooling.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Best configuration |
Index of best configuration simulated |
Capacity_ACH_SC_FP_W |
Thermal Capacity of Absorption Chiller connected to Flat-plate Solar Collector |
Capacity_ACHHT_FP_W |
Thermal Capacity of High Temperature Absorption Chiller connected to Solar Collector (flat Plate) |
Capacity_BaseVCC_AS_W |
Thermal Capacity of Base Vapor compression chiller (air-source) |
Capacity_DX_AS_W |
Thermal Capacity of Direct-Expansion Unit Air-source |
Capacity_VCCHT_AS_W |
Thermal Capacity of High Temperature Vapor compression chiller (air-source) |
Capaticy_ACH_SC_ET_W |
Thermal Capacity of Absorption Chiller connected to Evacuated-Tube Solar Collector |
Capex_a_USD |
Annualized Capital Costs |
Capex_total_USD |
Total Capital Costs |
GHG_tonCO2 |
Annual Green House Gas Emissions |
Nominal heating load |
Nominal heat load |
Opex_fixed_USD |
Fixed Annual Operational Costs |
Opex_var_USD |
Variable Annual Operational Costs |
TAC_USD |
Total Annualized Costs |
get_optimization_decentralized_folder_building_result_cooling_activation¶
path: outputs/data/optimization/decentralized/{building}_{configuration}_cooling_activation.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
E_ACH_req_W |
Electricity requirements of Absorption Chillers |
E_BaseVCC_AS_req_W |
Electricity requirements of Vapor Compression Chillers and refrigeration |
E_cs_cre_cdata_req_W |
Electricity requirements due to space cooling, servers cooling and refrigeration |
E_CT_req_W |
Electricity requirements of Cooling Towers |
E_DX_AS_req_W |
Electricity requirements of Air-Source direct expansion chillers |
E_SC_ET_req_W |
Electricity requirements of Solar Collectors (evacuated-tubes) |
E_SC_FP_req_W |
Electricity requirements of Solar Collectors (flat-plate) |
NG_Boiler_req |
Requirements of Natural Gas for Boilers |
NG_Burner_req |
Requirements of Natural Gas for Burners |
Q_ACH_gen_directload_W |
Thermal energy generated by Absorption chillers |
Q_BaseVCC_AS_gen_directload_W |
Thermal energy generated by Air-Source Vapor-compression chillers |
Q_Boiler_NG_ACH_W |
Thermal energy generated by Natural gas Boilers to Absorption chillers |
Q_Burner_NG_ACH_W |
Thermal energy generated by Natural gas Burners to Absorption chillers |
Q_DX_AS_gen_directload_W |
Thermal energy generated by Air-Source direct expansion chillers |
Q_SC_ET_ACH_W |
Thermal energy generated by Solar Collectors (evacuated-tubes) to Absorption chillers |
Q_SC_FP_ACH_W |
Thermal energy generated by Solar Collectors (flat-plate) to Absorption chillers |
get_optimization_decentralized_folder_building_result_heating¶
path: outputs/data/optimization/decentralized/DiscOp_B001_result_heating.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Best configuration |
Index of best configuration simulated |
Capacity_BaseBoiler_NG_W |
Thermal capacity of Baseload Boiler NG |
Capacity_FC_NG_W |
Thermal Capacity of Fuel Cell NG |
Capacity_GS_HP_W |
Thermal Capacity of Ground Source Heat Pump |
Capex_a_USD |
Annualized Capital Costs |
Capex_total_USD |
Total Capital Costs |
GHG_tonCO2 |
Annual Green House Gas Emissions |
Nominal heating load |
Nominal heat load |
Opex_fixed_USD |
Fixed Annual Operational Costs |
Opex_var_USD |
Variable Annual Operational Costs |
TAC_USD |
Total Annualized Costs |
get_optimization_decentralized_folder_building_result_heating_activation¶
path: outputs/data/optimization/decentralized/DiscOp_B001_result_heating_activation.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
BackupBoiler_Status |
Status of the BackupBoiler (1=on, 0 =off) |
BG_Boiler_req_W |
Requirements of Bio-gas for Base load Boiler |
Boiler_Status |
Status of the Base load Boiler (1=on, 0 =off) |
E_Fuelcell_gen_export_W |
Electricity generation of fuel cell exported to the grid |
E_hs_ww_req_W |
Electricity Requirements for heat pump compressor and auxiliary uses (if required) |
Fuelcell_Status |
Status of the fuel cell (1=on, 0 =off) |
GHP_Status |
Status of the ground-source heat pump (1=on, 0 =off) |
NG_BackupBoiler_req_W |
Requirements of Natural Gas for Back-up Boiler |
NG_Boiler_req_W |
Requirements of Natural Gas for Base load Boiler |
NG_FuelCell_req_W |
Requirements of Natural Gas for fuel cell |
Q_BackupBoiler_gen_directload_W |
Thermal generation of Back-up Boiler to direct load |
Q_Boiler_gen_directload_W |
Thermal generation of Base load Boiler to direct load |
Q_Fuelcell_gen_directload_W |
Thermal generation of fuel cell to direct load |
Q_GHP_gen_directload_W |
Thermal generation of ground-source heat pump to direct load |
get_optimization_district_scale_cooling_capacity¶
path: outputs/data/optimization/slave/gen_1/ind_1_district_scale_cooling_capacity.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capacity_ACH_SC_FP_cool_building_scale_W |
Thermal Capacity of Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
Capacity_ACHHT_FP_cool_building_scale_W |
Thermal Capacity of High-Temperature Absorption Chiller and Solar Collector (Flat Plate) for Decentralized Building |
Capacity_BaseVCC_AS_cool_building_scale_W |
Thermal Capacity of Base load Vapor Compression Chiller for Decentralized Building |
Capacity_DX_AS_cool_building_scale_W |
Thermal Capacity of Direct Expansion Air-Source for Decentralized Building |
Capacity_VCCHT_AS_cool_building_scale_W |
Thermal Capacity of High-Temperature Vapor Compression Chiller (Air-Source) for Decentralized Building |
Capaticy_ACH_SC_ET_cool_building_scale_W |
Thermal Capacity of Absorption Chiller and Solar Collector (Evacuated Tube)for Decentralized Building |
Name |
Unique building ID. It must start with a letter |
get_optimization_district_scale_electricity_capacity¶
path: outputs/data/optimization/slave/gen_2/ind_0_district_scale_electrical_capacity.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capacity_GRID_el_district_scale_W |
Electrical Capacity Required from the local Grid |
Capacity_PV_el_district_scale_m2 |
Area Coverage of PV in central Plant |
Capacity_PV_el_district_scale_W |
Electrical Capacity of PV in central Plant |
get_optimization_district_scale_heating_capacity¶
path: outputs/data/optimization/slave/gen_0/ind_2_district_scale_heating_capacity.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capacity_BackupBoiler_NG_heat_district_scale_W |
Thermal Capacity of Back-up Boiler - Natural Gas in central plant |
Capacity_BaseBoiler_NG_heat_district_scale_W |
Thermal Capacity of Base Load Boiler - Natural Gas in central plant |
Capacity_CHP_DB_el_district_scale_W |
Electrical Capacity of CHP Dry-Biomass in central plant |
Capacity_CHP_DB_heat_district_scale_W |
ThermalCapacity of CHP Dry-Biomass in central plant |
Capacity_CHP_NG_el_district_scale_W |
Electrical Capacity of CHP Natural-Gas in central plant |
Capacity_CHP_NG_heat_district_scale_W |
Thermal Capacity of CHP Natural-Gas in central plant |
Capacity_CHP_WB_el_district_scale_W |
Electrical Capacity of CHP Wet-Biomass in central plant |
Capacity_CHP_WB_heat_district_scale_W |
Thermal Capacity of CHP Wet-Biomass in central plant |
Capacity_HP_DS_heat_district_scale_W |
Thermal Capacity of Heat Pump Server-Source in central plant |
Capacity_HP_GS_heat_district_scale_W |
Thermal Capacity of Heat Pump Ground-Source in central plant |
Capacity_HP_SS_heat_district_scale_W |
Thermal Capacity of Heat Pump Sewage-Source in central plant |
Capacity_HP_WS_heat_district_scale_W |
Thermal Capacity of Heat Pump Water-Source in central plant |
Capacity_PeakBoiler_NG_heat_district_scale_W |
Thermal Capacity of Peak Boiler - Natural Gas in central plant |
Capacity_PVT_el_district_scale_W |
Electrical Capacity of PVT Field in central plant |
Capacity_PVT_heat_district_scale_W |
Thermal Capacity of PVT panels in central plant |
Capacity_SC_ET_heat_district_scale_W |
Thermal Capacity of Solar Collectors (Evacuated-tube) in central plant |
Capacity_SC_FP_heat_district_scale_W |
Thermal Capacity of Solar Collectors (Flat-plate) in central plant |
Capacity_SeasonalStorage_WS_heat_district_scale_W |
Thermal Capacity of Seasonal Thermal Storage in central plant |
get_optimization_generation_building_scale_performance¶
path: outputs/data/optimization/slave/gen_2/gen_2_building_scale_performance.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_cooling_building_scale_USD |
Annualized Capital Costs of building-scale systems due to cooling |
Capex_a_heating_building_scale_USD |
Annualized Capital Costs of building-scale systems due to heating |
Capex_total_cooling_building_scale_USD |
Total Capital Costs of building-scale systems due to cooling |
Capex_total_heating_building_scale_USD |
Total Capital Costs of building-scale systems due to heating |
generation |
No. Generation or Iteration (genetic Algorithm) |
GHG_cooling_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems due to Cooling |
GHG_heating_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems due to Heating |
individual |
No. Individual unique ID |
individual_name |
Name of Individual unique ID |
Opex_fixed_cooling_building_scale_USD |
Fixed Operational Costs of building-scale systems due to cooling |
Opex_fixed_heating_building_scale_USD |
Fixed Operational Costs of building-scale systems due to heating |
Opex_var_cooling_building_scale_USD |
Variable Operational Costs of building-scale systems due to cooling |
Opex_var_heating_building_scale_USD |
Variable Operational Costs of building-scale systems due to heating |
get_optimization_generation_district_scale_performance¶
path: outputs/data/optimization/slave/gen_1/gen_1_district_scale_performance.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_BackupBoiler_NG_district_scale_USD |
Annualized Capital Costs of Back-up Boiler Natural Gas in Central Plant |
Capex_a_BaseBoiler_NG_district_scale_USD |
Annualized Capital Costs of Base Load Boiler Boiler Natural Gas in Central Plant |
Capex_a_CHP_NG_district_scale_USD |
Annualized Capital Costs of CHP Natural Gas in Central Plant |
Capex_a_DHN_district_scale_USD |
Annualized Capital Costs of District Heating Network |
Capex_a_Furnace_dry_district_scale_USD |
Annualized Capital Costs of CHP Dry-Biomass in Central Plant |
Capex_a_Furnace_wet_district_scale_USD |
Annualized Capital Costs of CHP Wet-Biomass in Central Plant |
Capex_a_GHP_district_scale_USD |
Annualized Capital Costs of Ground-Source Heat Pump in Central Plant |
Capex_a_GRID_district_scale_USD |
Annualized Capital Costs of connection to local electrical grid |
Capex_a_HP_Lake_district_scale_USD |
Annualized Capital Costs of Lake-Source Heat Pump in Central Plant |
Capex_a_HP_Server_district_scale_USD |
Annualized Capital Costs of Server-Source Heat Pump in Central Plant |
Capex_a_HP_Sewage_district_scale_USD |
Annualized Capital Costs of Sewage-Source Heat Pump in Central Plant |
Capex_a_PeakBoiler_NG_district_scale_USD |
Annualized Capital Costs of Peak Load Boiler Boiler Natural Gas in Central Plant |
Capex_a_PV_district_scale_USD |
Annualized Capital Costs of Photovoltaic Panels in Central Plant |
Capex_a_PVT_district_scale_USD |
Annualized Capital Costs of PVT Panels in Central Plant |
Capex_a_SC_ET_district_scale_USD |
Annualized Capital Costs of Solar Collectors (evacuated-Tube) in Central Plant |
Capex_a_SC_FP_district_scale_USD |
Annualized Capital Costs of Solar Collectors (Flat-Plate) in Central Plant |
Capex_a_SeasonalStorage_WS_district_scale_USD |
Annualized Capital Costs of Seasonal Thermal Storage in Central Plant |
Capex_a_SubstationsHeating_district_scale_USD |
Annualized Capital Costs of Thermal Substations |
Capex_total_BackupBoiler_NG_district_scale_USD |
Total Capital Costs of Back-up Boiler Natural Gas in Central Plant |
Capex_total_BaseBoiler_NG_district_scale_USD |
Total Capital Costs of Base Load Boiler Boiler Natural Gas in Central Plant |
Capex_total_CHP_NG_district_scale_USD |
Total Capital Costs of CHP Natural Gas in Central Plant |
Capex_total_DHN_district_scale_USD |
Total Capital Costs of District Heating Network |
Capex_total_Furnace_dry_district_scale_USD |
Total Capital Costs of CHP Dry-Biomass in Central Plant |
Capex_total_Furnace_wet_district_scale_USD |
Total Capital Costs of CHP Wet-Biomass in Central Plant |
Capex_total_GHP_district_scale_USD |
Total Capital Costs of Ground-Source Heat Pump in Central Plant |
Capex_total_GRID_district_scale_USD |
Total Capital Costs of connection to local electrical grid |
Capex_total_HP_Lake_district_scale_USD |
Total Capital Costs of Lake-Source Heat Pump in Central Plant |
Capex_total_HP_Server_district_scale_USD |
Total Capital Costs of Server-Source Heat Pump in Central Plant |
Capex_total_HP_Sewage_district_scale_USD |
Total Capital Costs of Sewage-Source Heat Pump in Central Plant |
Capex_total_PeakBoiler_NG_district_scale_USD |
Total Capital Costs of Peak Load Boiler Boiler Natural Gas in Central Plant |
Capex_total_PV_district_scale_USD |
Total Capital Costs of Photovoltaic Panels in Central Plant |
Capex_total_PVT_district_scale_USD |
Total Capital Costs of PVT Panels in Central Plant |
Capex_total_SC_ET_district_scale_USD |
Total Capital Costs of Solar Collectors (evacuated-Tube) in Central Plant |
Capex_total_SC_FP_district_scale_USD |
Total Capital Costs of Solar Collectors (Flat-Plate) in Central Plant |
Capex_total_SeasonalStorage_WS_district_scale_USD |
Total Capital Costs of Seasonal Thermal Storage in Central Plant |
Capex_total_SubstationsHeating_district_scale_USD |
Total Capital Costs of Thermal Substations |
generation |
Number of the Generation or Iteration (Genetic algorithm) |
GHG_DB_district_scale_tonCO2yr |
Green House Gas Emissions of Dry-Biomass of district-scale systems |
GHG_GRID_exports_district_scale_tonCO2yr |
Green House Gas Emissions of Exports of Electricity |
GHG_GRID_imports_district_scale_tonCO2yr |
Green House Gas Emissions of Import of Electricity |
GHG_NG_district_scale_tonCO2yr |
Green House Gas Emissions of Natural Gas of district-scale systems |
GHG_WB_district_scale_tonCO2yr |
Green House Gas Emissions of Wet-Biomass of district-scale systems |
individual |
Unique numerical ID of individual |
individual_name |
Unique alphanumerical ID of individual |
Opex_fixed_BackupBoiler_NG_district_scale_USD |
Fixed Operation Costs of Back-up Boiler Natural Gas in Central Plant |
Opex_fixed_BaseBoiler_NG_district_scale_USD |
Fixed Operation Costs of Base Load Boiler Boiler Natural Gas in Central Plant |
Opex_fixed_CHP_NG_district_scale_USD |
Fixed Operation Costs of CHP Natural Gas in Central Plant |
Opex_fixed_DHN_district_scale_USD |
Fixed Operation Costs of District Heating Network |
Opex_fixed_Furnace_dry_district_scale_USD |
Fixed Operation Costs of CHP Dry-Biomass in Central Plant |
Opex_fixed_Furnace_wet_district_scale_USD |
Fixed Operation Costs of CHP Wet-Biomass in Central Plant |
Opex_fixed_GHP_district_scale_USD |
Fixed Operation Costs of Ground-Source Heat Pump in Central Plant |
Opex_fixed_GRID_district_scale_USD |
Fixed Operation Costs of Electricity in Buildings Connected to Central Plant |
Opex_fixed_HP_Lake_district_scale_USD |
Fixed Operation Costs of Lake-Source Heat Pump in Central Plant |
Opex_fixed_HP_Server_district_scale_USD |
Fixed Operation Costs of Server-Source Heat Pump in Central Plant |
Opex_fixed_HP_Sewage_district_scale_USD |
Fixed Operation Costs of Sewage-Source Heat Pump in Central Plant |
Opex_fixed_PeakBoiler_NG_district_scale_USD |
Fixed Operation Costs of Peak Load Boiler Boiler Natural Gas in Central Plant |
Opex_fixed_PV_district_scale_USD |
Fixed Operation Costs of Photovoltaic Panels in Central Plant |
Opex_fixed_PVT_district_scale_USD |
Fixed Operation Costs of PVT Panels in Central Plant |
Opex_fixed_SC_ET_district_scale_USD |
Fixed Operation Costs of Solar Collectors (evacuated-Tube) in Central Plant |
Opex_fixed_SC_FP_district_scale_USD |
Fixed Operation Costs of Solar Collectors (Flat-Plate) in Central Plant |
Opex_fixed_SeasonalStorage_WS_district_scale_USD |
Fixed Operation Costs of Seasonal Thermal Storage in Central Plant |
Opex_fixed_SubstationsHeating_district_scale_USD |
Fixed Operation Costs of Thermal Substations |
Opex_var_DB_district_scale_USD |
Variable Operation Costs due to consumption of Dry-Biomass in Central Plant |
Opex_var_GRID_exports_district_scale_USD |
Variable Operation Costs due to electricity exported |
Opex_var_GRID_imports_district_scale_USD |
Variable Operation Costs due to electricity imported |
Opex_var_NG_district_scale_USD |
Variable Operation Costs due to consumption of Natural Gas in Central Plant |
Opex_var_WB_district_scale_USD |
Variable Operation Costs due to consumption of Wet-Biomass in Central Plant |
get_optimization_generation_total_performance¶
path: outputs/data/optimization/slave/gen_2/gen_2_total_performance.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_sys_building_scale_USD |
Annualized Capital Costs of building-scale systems |
Capex_a_sys_district_scale_USD |
Annualized Capital Costs of district-scale systems |
Capex_a_sys_USD |
Annualized Capital Costs of all systems |
Capex_total_sys_building_scale_USD |
Total Capital Costs of building-scale systems |
Capex_total_sys_district_scale_USD |
Total Capital Costs of district-scale systems |
Capex_total_sys_USD |
Total Capital Costs of district-scale systems and Decentralized Buildings |
generation |
No. Generation or Iteration (genetic Algorithm) |
GHG_sys_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems |
GHG_sys_district_scale_tonCO2 |
Green House Gas Emissions Central Plant |
GHG_sys_tonCO2 |
Green House Gas Emissions of all systems |
individual |
No. Individual unique ID |
individual_name |
Name of Individual unique ID |
Opex_a_sys_building_scale_USD |
Operation Costs of building-scale systems |
Opex_a_sys_district_scale_USD |
Operation Costs of district-scale systems |
Opex_a_sys_USD |
Operation Costs of all systems |
TAC_sys_building_scale_USD |
Total Anualized Costs of building-scale systems |
TAC_sys_district_scale_USD |
Total Anualized Costs of district-scale systems |
TAC_sys_USD |
Total Anualized Costs of all systems |
get_optimization_generation_total_performance_pareto¶
path: outputs/data/optimization/slave/gen_2/gen_2_total_performance_pareto.csv
The following file is used by these scripts: multi_criteria_analysis
Variable | Description |
---|---|
Capex_a_sys_building_scale_USD |
Annualized Capital Costs of building-scale systems |
Capex_a_sys_district_scale_USD |
Annualized Capital Costs of district-scale systems |
Capex_a_sys_USD |
Annualized Capital Costs of all systems |
Capex_total_sys_building_scale_USD |
Total Capital Costs of building-scale systems |
Capex_total_sys_district_scale_USD |
Total Capital Costs of district-scale systems |
Capex_total_sys_USD |
Total Capital Costs of district-scale systems and Decentralized Buildings |
generation |
No. Generation or Iteration (genetic Algorithm) |
GHG_sys_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems |
GHG_sys_district_scale_tonCO2 |
Green House Gas Emissions Central Plant |
GHG_sys_tonCO2 |
Green House Gas Emissions of all systems |
individual |
No. Individual unique ID |
individual_name |
Name of Individual unique ID |
Opex_a_sys_building_scale_USD |
Operation Costs of building-scale systems |
Opex_a_sys_district_scale_USD |
Operation Costs of district-scale systems |
Opex_a_sys_USD |
Operation Costs of all systems |
TAC_sys_building_scale_USD |
Total Anualized Costs of building-scale systems |
TAC_sys_district_scale_USD |
Total Anualized Costs of district-scale systems |
TAC_sys_USD |
Total Anualized Costs of all systems |
get_optimization_individuals_in_generation¶
path: outputs/data/optimization/slave/gen_2/generation_2_individuals.csv
The following file is used by these scripts:
Variable | Description |
---|---|
B01_DH |
TODO |
B02_DH |
TODO |
B03_DH |
TODO |
B04_DH |
TODO |
B05_DH |
TODO |
B06_DH |
TODO |
B07_DH |
TODO |
B08_DH |
TODO |
B09_DH |
TODO |
DB_Cogen |
TODO |
DS_HP |
TODO |
generation |
TODO |
GS_HP |
TODO |
individual |
TODO |
NG_BaseBoiler |
TODO |
NG_Cogen |
TODO |
NG_PeakBoiler |
TODO |
PV |
TODO |
PVT |
TODO |
SC_ET |
TODO |
SC_FP |
TODO |
SS_HP |
TODO |
WB_Cogen |
TODO |
WS_HP |
TODO |
get_optimization_network_results_summary¶
path: outputs/data/optimization/network/DH_Network_summary_result_0x1be.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
DATE |
Time stamp (hourly) for one year |
mcpdata_netw_total_kWperC |
Capacity mass flow reate for server cooling of this network |
mdot_DH_netw_total_kgpers |
Total mass flow rate in this district heating network |
Q_DH_losses_W |
Thermal losses of this district heating network |
Q_DHNf_W |
Total thermal demand of district heating network |
Qcdata_netw_total_kWh |
Thermal Demand for server cooling in this network |
T_DHNf_re_K |
Average Temperature of return of this district heating network |
T_DHNf_sup_K |
Average Temperature of supply of this district heating network |
get_optimization_slave_building_connectivity¶
path: outputs/data/optimization/slave/gen_2/ind_1_building_connectivity.csv
The following file is used by these scripts:
Variable | Description |
---|---|
DC_connectivity |
Flag to know if building is connected to District Heating or not |
DH_connectivity |
Flag to know if building is connected to District Cooling or not |
Name |
Unique building ID. It must start with a letter.) |
get_optimization_slave_building_scale_performance¶
path: outputs/data/optimization/slave/gen_2/ind_0_buildings_building_scale_performance.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_cooling_building_scale_USD |
Annualized Capital Costs of building-scale systems due to cooling |
Capex_a_heating_building_scale_USD |
Annualized Capital Costs of building-scale systems due to heating |
Capex_total_cooling_building_scale_USD |
Total Capital Costs of building-scale systems due to cooling |
Capex_total_heating_building_scale_USD |
Total Capital Costs of building-scale systems due to heating |
GHG_cooling_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems due to Cooling |
GHG_heating_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems due to Heating |
Opex_fixed_cooling_building_scale_USD |
Fixed Operational Costs of building-scale systems due to cooling |
Opex_fixed_heating_building_scale_USD |
Fixed Operational Costs of building-scale systems due to heating |
Opex_var_cooling_building_scale_USD |
Variable Operational Costs of building-scale systems due to cooling |
Opex_var_heating_building_scale_USD |
Variable Operational Costs of building-scale systems due to heating |
get_optimization_slave_cooling_activation_pattern¶
path: outputs/data/optimization/slave/gen_1/ind_2_Cooling_Activation_Pattern.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Capacity_DailyStorage_WS_cool_district_scale_W |
Installed capacity of the short-term thermal storage |
Capex_a_DailyStorage_WS_cool_district_scale_USD |
Annualized capital costs of the short-term thermal storage |
Capex_total_DailyStorage_WS_cool_district_scale_USD |
Total capital costs of the short-term thermal storage |
Opex_fixed_DailyStorage_WS_cool_district_scale_USD |
Fixed operational costs of the short-term thermal storage |
Q_DailyStorage_content_W |
Thermal energy content of the short-term thermal storage |
Q_DailyStorage_gen_directload_W |
Thermal energy supplied from the short-term thermal storage |
get_optimization_slave_district_scale_performance¶
path: outputs/data/optimization/slave/gen_1/ind_2_buildings_district_scale_performance.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_BackupBoiler_NG_district_scale_USD |
Annualized Capital Costs of Back-up Boiler Natural Gas in Central Plant |
Capex_a_BaseBoiler_NG_district_scale_USD |
Annualized Capital Costs of Base load Boiler Natural Gas in Central Plant |
Capex_a_CHP_NG_district_scale_USD |
Annualized Capital Costs of CHP Natural Gas in Central Plant |
Capex_a_DHN_district_scale_USD |
Annualized Capital Costs of District Heating Network |
Capex_a_Furnace_dry_district_scale_USD |
Annualized Capital Costs of CHP Dry-Biomass in Central Plant |
Capex_a_Furnace_wet_district_scale_USD |
Annualized Capital Costs of CHP Wet-Biomass in Central Plant |
Capex_a_GHP_district_scale_USD |
Annualized Capital Costs of Ground-Source Heat-Pump in Central Plant |
Capex_a_GRID_district_scale_USD |
Annualized Capital Costs of connection to local grid |
Capex_a_HP_Lake_district_scale_USD |
Annualized Capital Costs of Lake-Source Heat Pump in Central Plant |
Capex_a_HP_Server_district_scale_USD |
Annualized Capital Costs of Server-Source Heat Pump in Central Plant |
Capex_a_HP_Sewage_district_scale_USD |
Annualized Capital Costs of Sewage-Source Heat Pump in Central Plant |
Capex_a_PeakBoiler_NG_district_scale_USD |
Annualized Capital Costs of Peak Boiler in Central Plant |
Capex_a_PV_district_scale_USD |
Annualized Capital Costs of PV panels |
Capex_a_PVT_district_scale_USD |
Annualized Capital Costs of PVT panels |
Capex_a_SC_ET_district_scale_USD |
Annualized Capital Costs of Solar collectors (evacuated Tubes) |
Capex_a_SC_FP_district_scale_USD |
Annualized Capital Costs of Solar collectors (Flat-Plate) |
Capex_a_SeasonalStorage_WS_district_scale_USD |
Annualized Capital Costs of Seasonal Thermal Storage in Central Plant |
Capex_a_SubstationsHeating_district_scale_USD |
Annualized Capital Costs of Heating Substations |
Capex_total_BackupBoiler_NG_district_scale_USD |
Total Capital Costs of Back-up Boiler Natural Gas in Central Plant |
Capex_total_BaseBoiler_NG_district_scale_USD |
Total Capital Costs of Base load Boiler Natural Gas in Central Plant |
Capex_total_CHP_NG_district_scale_USD |
Total Capital Costs of CHP Natural Gas in Central Plant |
Capex_total_DHN_district_scale_USD |
Total Capital Costs of District Heating Network |
Capex_total_Furnace_dry_district_scale_USD |
Total Capital Costs of CHP Dry-Biomass in Central Plant |
Capex_total_Furnace_wet_district_scale_USD |
Total Capital Costs of CHP Wet-Biomass in Central Plant |
Capex_total_GHP_district_scale_USD |
Total Capital Costs of Ground-Source Heat-Pump in Central Plant |
Capex_total_GRID_district_scale_USD |
Total Capital Costs of connection to local grid |
Capex_total_HP_Lake_district_scale_USD |
Total Capital Costs of Lake-Source Heat Pump in Central Plant |
Capex_total_HP_Server_district_scale_USD |
Total Capital Costs of Server-Source Heat Pump in Central Plant |
Capex_total_HP_Sewage_district_scale_USD |
Total Capital Costs of Sewage-Source Heat Pump in Central Plant |
Capex_total_PeakBoiler_NG_district_scale_USD |
Total Capital Costs of Peak Boiler in Central Plant |
Capex_total_PV_district_scale_USD |
Total Capital Costs of PV panels |
Capex_total_PVT_district_scale_USD |
Total Capital Costs of PVT panels |
Capex_total_SC_ET_district_scale_USD |
Total Capital Costs of Solar collectors (evacuated Tubes) |
Capex_total_SC_FP_district_scale_USD |
Total Capital Costs of Solar collectors (Flat-Plate) |
Capex_total_SeasonalStorage_WS_district_scale_USD |
Total Capital Costs of Seasonal Thermal Storage |
Capex_total_SubstationsHeating_district_scale_USD |
Total Capital Costs of Heating Substations |
GHG_DB_district_scale_tonCO2yr |
Green House Gas Emissions of Dry-Biomass in Central plant |
GHG_GRID_exports_district_scale_tonCO2yr |
Green House Gas Emissions of Electricity Exports in Central Plant |
GHG_GRID_imports_district_scale_tonCO2yr |
Green House Gas Emissions of Electricity Import in Central Plant |
GHG_NG_district_scale_tonCO2yr |
Green House Gas Emissions of Natural Gas in Central plant |
GHG_WB_district_scale_tonCO2yr |
Green House Gas Emissions of Wet-Biomass in Central plant |
Opex_fixed_BackupBoiler_NG_district_scale_USD |
Fixed Operation Costs of Back-up Boiler Natural Gas in Central Plant |
Opex_fixed_BaseBoiler_NG_district_scale_USD |
Fixed Operation Costs of Base load Boiler Natural Gas in Central Plant |
Opex_fixed_CHP_NG_district_scale_USD |
Fixed Operation Costs of CHP Natural Gas in Central Plant |
Opex_fixed_DHN_district_scale_USD |
Fixed Operation Costs of District Heating Network |
Opex_fixed_Furnace_dry_district_scale_USD |
Fixed Operation Costs of CHP Dry-Biomass in Central Plant |
Opex_fixed_Furnace_wet_district_scale_USD |
Fixed Operation Costs of CHP Wet-Biomass in Central Plant |
Opex_fixed_GHP_district_scale_USD |
Fixed Operation Costs of Ground-Source Heat-Pump in Central Plant |
Opex_fixed_GRID_district_scale_USD |
Fixed Operation Costs of connection to local grid |
Opex_fixed_HP_Lake_district_scale_USD |
Fixed Operation Costs of Lake-Source Heat Pump in Central Plant |
Opex_fixed_HP_Server_district_scale_USD |
Fixed Operation Costs of Server-Source Heat Pump in Central Plant |
Opex_fixed_HP_Sewage_district_scale_USD |
Fixed Operation Costs of Sewage-Source Heat Pump in Central Plant |
Opex_fixed_PeakBoiler_NG_district_scale_USD |
Fixed Operation Costs of Peak Boiler in Central Plant |
Opex_fixed_PV_district_scale_USD |
Fixed Operation Costs of PV panels |
Opex_fixed_PVT_district_scale_USD |
Fixed Operation Costs of PVT panels |
Opex_fixed_SC_ET_district_scale_USD |
Fixed Operation Costs of Solar collectors (evacuated Tubes) |
Opex_fixed_SC_FP_district_scale_USD |
Fixed Operation Costs of Solar collectors (Flat-Plate) |
Opex_fixed_SeasonalStorage_WS_district_scale_USD |
Fixed Operation Costs of Seasonal Thermal Storage |
Opex_fixed_SubstationsHeating_district_scale_USD |
Fixed Operation Costs of Heating Substations |
Opex_var_DB_district_scale_USD |
Variable Operation Costs |
Opex_var_GRID_exports_district_scale_USD |
Variable Operation Costs |
Opex_var_GRID_imports_district_scale_USD |
Variable Operation Costs |
Opex_var_NG_district_scale_USD |
Variable Operation Costs |
Opex_var_WB_district_scale_USD |
Variable Operation Costs |
get_optimization_slave_electricity_activation_pattern¶
path: outputs/data/optimization/slave/gen_1/ind_1_Electricity_Activation_Pattern.csv
The following file is used by these scripts:
Variable | Description |
---|---|
DATE |
Time stamp (hourly) for one year |
E_CHP_gen_directload_W |
Electricity Generated to direct load by CHP Natural Gas |
E_CHP_gen_export_W |
Electricity Exported by CHP Natural Gas |
E_Furnace_dry_gen_directload_W |
Electricity Generated to direct load by CHP Dry Biomass |
E_Furnace_dry_gen_export_W |
Electricity Exported by CHP Dry Biomass |
E_Furnace_wet_gen_directload_W |
Electricity Generated to direct load by CHP Wet Biomass |
E_Furnace_wet_gen_export_W |
Electricity Exported by CHP Wet Biomass |
E_GRID_directload_W |
Electricity Imported from the local grid |
E_PV_gen_directload_W |
Electricity Generated to direct load by PV panels |
E_PV_gen_export_W |
Electricity Exported by PV panels |
E_PVT_gen_directload_W |
Electricity Generated to direct load by PVT panels |
E_PVT_gen_export_W |
Electricity Exported by PVT panels |
E_Trigen_gen_directload_W |
Electricity Generated to direct load by Trigen CHP Natural Gas |
E_Trigen_gen_export_W |
Electricity Exported by Trigen CHP Natural Gas |
get_optimization_slave_electricity_requirements_data¶
path: outputs/data/optimization/slave/gen_1/ind_1_Electricity_Requirements_Pattern.csv
The following file is used by these scripts:
Variable | Description |
---|---|
DATE |
Time stamp (hourly) for one year |
E_BackupBoiler_req_W |
Electricity (auxiliary) Required by Back-up Boiler |
E_BackupVCC_AS_req_W |
Electricity Required by Back-up Vapor Compression Chiller (Air-Source) |
E_BaseBoiler_req_W |
Electricity (auxiliary) Required by Base Load Boiler |
E_BaseVCC_AS_req_W |
Electricity Required by Base Load Vapor Compression Chiller (Air-Source) |
E_BaseVCC_WS_req_W |
Electricity Required by Base Load Vapor Compression Chiller (Water-Source) |
E_cs_cre_cdata_req_building_scale_W |
Electricity Required for space cooling, server cooling and refrigeration of building-scale systems |
E_cs_cre_cdata_req_district_scale_W |
Electricity Required for space cooling, server cooling and refrigeration of Buildings Connected to Network |
E_DCN_req_W |
Electricity Required for Chilled water Pumping in District Cooling Network |
E_DHN_req_W |
Electricity Required for Chilled water Pumping in District Heating Network |
E_electricalnetwork_sys_req_W |
Total Electricity Requirements |
E_GHP_req_W |
Electricity Required by Ground-Source Heat Pumps |
E_HP_Lake_req_W |
Electricity Required by Lake-Source Heat Pumps |
E_HP_PVT_req_W |
Electricity Required by Auxiliary Heat Pumps of PVT panels |
E_HP_SC_ET_req_W |
Electricity Required by Auxiliary Heat Pumps of Solar collectors (Evacuated tubes) |
E_HP_SC_FP_req_W |
Electricity Required by Auxiliary Heat Pumps of Solar collectors (Evacuated Flat Plate) |
E_HP_Server_req_W |
Electricity Required by Server-Source Heat Pumps |
E_HP_Sew_req_W |
Electricity Required by Sewage-Source Heat Pumps |
E_hs_ww_req_building_scale_W |
Electricity Required for space heating and hotwater of building-scale systems |
E_hs_ww_req_district_scale_W |
Electricity Required for space heating and hotwater of Buildings Connected to Network |
E_PeakBoiler_req_W |
Electricity (auxiliary) Required by Peak-Boiler |
E_PeakVCC_AS_req_W |
Electricity Required by Peak Vapor Compression Chiller (Air-Source) |
E_PeakVCC_WS_req_W |
Electricity Required by Peak Vapor Compression Chiller (Water-Source) |
E_Storage_charging_req_W |
Electricity Required by Auxiliary Heatpumps for charging Seasonal Thermal Storage |
E_Storage_discharging_req_W |
Electricity Required by Auxiliary Heatpumps for discharging Seasonal Thermal Storage |
Eal_req_W |
Electricity Required for Appliances and Lighting in all Buildings |
Eaux_req_W |
Electricity Required for Fans and others in all Buildings |
Edata_req_W |
Electricity Required for Servers in all Buildings |
Epro_req_W |
Electricity Required for Industrial Processes in all Buildings |
get_optimization_slave_heating_activation_pattern¶
path: outputs/data/optimization/slave/gen_2/ind_0_Heating_Activation_Pattern.csv
The following file is used by these scripts:
Variable | Description |
---|---|
DATE |
Time stamp (hourly) for one year |
E_CHP_gen_W |
Electricity Generation by CHP Natural Gas |
E_Furnace_dry_gen_W |
Electricity Generation by CHP Dry-Biomass |
E_Furnace_wet_gen_W |
Electricity Generation by CHP Wet-Biomass |
E_PVT_gen_W |
Electricity Generation by PVT |
Q_BackupBoiler_gen_directload_W |
Thermal generation of Back-up Boiler to direct load |
Q_BaseBoiler_gen_directload_W |
Thermal generation of Base load Boiler to direct load |
Q_CHP_gen_directload_W |
Thermal generation of CHP Natural Gas to direct load |
Q_districtheating_sys_req_W |
Thermal requirements of District Heating Network |
Q_Furnace_dry_gen_directload_W |
Thermal generation of CHP Dry-Biomass to direct load |
Q_Furnace_wet_gen_directload_W |
Thermal generation of CHP Wet-Biomass to direct load |
Q_GHP_gen_directload_W |
Thermal generation of ground-source heat pump to direct load |
Q_HP_Lake_gen_directload_W |
Thermal generation of Lake-Source Heatpump to direct load |
Q_HP_Server_gen_directload_W |
Thermal generation of Server-Source Heatpump to direct load |
Q_HP_Server_storage_W |
Thermal generation of Server-Source Heatpump to Seasonal Thermal Storage |
Q_HP_Sew_gen_directload_W |
Thermal generation of Sewage-Source Heatpump to direct load |
Q_PeakBoiler_gen_directload_W |
Thermal generation of Peak Boiler to direct load |
Q_PVT_gen_directload_W |
Thermal generation of PVT to direct load |
Q_PVT_gen_storage_W |
Thermal generation of PVT to Seasonal Thermal Storage |
Q_SC_ET_gen_directload_W |
Thermal generation of Solar Collectors (Evacuated Tubes) to direct load |
Q_SC_ET_gen_storage_W |
Thermal generation of Solar Collectors (Evacuated Tubes) to Seasonal Thermal Storage |
Q_SC_FP_gen_directload_W |
Thermal generation of Solar Collectors (Flat Plate) to direct load |
Q_SC_FP_gen_storage_W |
Thermal generation of Solar Collectors (Flat Plate) to Seasonal Thermal Storage |
Q_Storage_gen_directload_W |
Discharge from Storage to Direct Load |
get_optimization_slave_total_performance¶
path: outputs/data/optimization/slave/gen_0/ind_2_total_performance.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Capex_a_sys_building_scale_USD |
Annualized Capital Costs of building-scale systems |
Capex_a_sys_district_scale_USD |
Annualized Capital Costs of district-scale systems |
Capex_a_sys_USD |
Annualized Capital Costs of all systems |
Capex_total_sys_building_scale_USD |
Total Capital Costs of building-scale systems |
Capex_total_sys_district_scale_USD |
Total Capital Costs of district-scale systems |
Capex_total_sys_USD |
Total Capital Costs of all systems |
GHG_sys_building_scale_tonCO2 |
Green House Gas Emissions of building-scale systems |
GHG_sys_district_scale_tonCO2 |
Green House Gas Emissions Central Plant |
GHG_sys_tonCO2 |
Green House Gas Emissions of all systems |
Opex_a_sys_building_scale_USD |
Operation Costs of building-scale systems |
Opex_a_sys_district_scale_USD |
Operation Costs of district-scale systems |
Opex_a_sys_USD |
Operation Costs of all systems |
TAC_sys_building_scale_USD |
Total Anualized Costs of building-scale systems |
TAC_sys_district_scale_USD |
Total Anualized Costs of district-scale systems |
TAC_sys_USD |
Total Anualized Costs of all systems |
get_optimization_substations_results_file¶
path: outputs/data/optimization/substations/110011011DH_B001_result.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
A_hex_dhw_design_m2 |
Substation heat exchanger area to supply domestic hot water |
A_hex_heating_design_m2 |
Substation heat exchanger area to supply space heating |
mdot_DH_result_kgpers |
Substation flow rate on the DH side. |
Q_dhw_W |
Substation heat requirement to supply domestic hot water |
Q_heating_W |
Substation heat requirement to supply space heating |
T_return_DH_result_K |
Substation return temperature of the district heating network |
T_supply_DH_result_K |
Substation supply temperature of the district heating network. |
get_optimization_substations_total_file¶
path: outputs/data/optimization/substations/Total_DH_111111111.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Af_m2 |
Conditioned floor area (heated/cooled) |
Aocc_m2 |
Occupied floor area (heated/cooled) |
Aroof_m2 |
Roof area |
COAL_hs0_kW |
Nominal Coal requirement for space heating supply |
COAL_hs_MWhyr |
Coal requirement for space heating supply |
COAL_ww0_kW |
Nominal Coal requirement for hotwater supply |
COAL_ww_MWhyr |
Coal requirement for hotwater supply |
DC_cdata0_kW |
Nominal district cooling for final data center cooling demand |
DC_cdata_MWhyr |
District cooling for data center cooling demand |
DC_cre0_kW |
Nominal district cooling for refrigeration demand |
DC_cre_MWhyr |
District cooling for refrigeration demand |
DC_cs0_kW |
Nominal district cooling for space cooling demand |
DC_cs_MWhyr |
Energy consumption of space cooling system (if supplied by District Cooling), DC_cs = Qcs_sys / eff_cs |
DH_hs0_kW |
Nominal energy requirement by district heating (space heating supply) |
DH_hs_MWhyr |
Energy requirement by district heating (space heating supply) |
DH_ww0_kW |
Nominal Energy requirement by district heating (hotwater supply) |
DH_ww_MWhyr |
Energy requirement by district heating (hotwater supply) |
E_cdata0_kW |
Nominal Data centre cooling specific electricity consumption. |
E_cdata_MWhyr |
Electricity consumption due to data center cooling |
E_cre0_kW |
Nominal Refrigeration system electricity consumption. |
E_cre_MWhyr |
Electricity consumption due to refrigeration |
E_cs0_kW |
Nominal Cooling system electricity consumption. |
E_cs_MWhyr |
Energy consumption of cooling system (if supplied by electricity grid), E_cs = Qcs_sys / eff_cs |
E_hs0_kW |
Nominal Heating system electricity consumption. |
E_hs_MWhyr |
Electricity consumption due to space heating |
E_sys0_kW |
Nominal end-use electricity demand |
E_sys_MWhyr |
End-use total electricity consumption, E_sys = Eve + Ea + El + Edata + Epro + Eaux + Ev |
E_ww0_kW |
Nominal Domestic hot water electricity consumption. |
E_ww_MWhyr |
Electricity consumption due to hot water |
Ea0_kW |
Nominal end-use electricity for appliances |
Ea_MWhyr |
End-use electricity for appliances |
Eal0_kW |
Nominal Total net electricity for all sources and sinks. |
Eal_MWhyr |
End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W |
Eaux0_kW |
Nominal Auxiliary electricity consumption. |
Eaux_MWhyr |
End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux |
Edata0_kW |
Nominal Data centre electricity consumption. |
Edata_MWhyr |
Electricity consumption for data centers |
El0_kW |
Nominal end-use electricity for lights |
El_MWhyr |
End-use electricity for lights |
Epro0_kW |
Nominal Industrial processes electricity consumption. |
Epro_MWhyr |
Electricity supplied to industrial processes |
Ev0_kW |
Nominal end-use electricity for electric vehicles |
Ev_MWhyr |
End-use electricity for electric vehicles |
Eve0_kW |
Nominal end-use electricity for ventilation |
Eve_MWhyr |
End-use electricity for ventilation |
GFA_m2 |
Gross floor area |
GRID0_kW |
Nominal Grid electricity consumption |
GRID_a0_kW |
Nominal grid electricity requirements for appliances |
GRID_a_MWhyr |
Grid electricity requirements for appliances |
GRID_aux0_kW |
Nominal grid electricity requirements for auxiliary loads |
GRID_aux_MWhyr |
Grid electricity requirements for auxiliary loads |
GRID_cdata0_kW |
Nominal grid electricity requirements for servers cooling |
GRID_cdata_MWhyr |
Grid electricity requirements for servers cooling |
GRID_cre0_kW |
Nominal grid electricity requirements for refrigeration |
GRID_cre_MWhyr |
Grid electricity requirements for refrigeration |
GRID_cs0_kW |
Nominal grid electricity requirements for space cooling |
GRID_cs_MWhyr |
Grid electricity requirements for space cooling |
GRID_data0_kW |
Nominal grid electricity requirements for servers |
GRID_data_MWhyr |
Grid electricity requirements for servers |
GRID_hs0_kW |
Nominal grid electricity requirements for space heating |
GRID_hs_MWhyr |
Grid electricity requirements for space heating |
GRID_l0_kW |
Nominal grid electricity consumption for lights |
GRID_l_MWhyr |
Grid electricity requirements for lights |
GRID_MWhyr |
Grid electricity consumption, GRID = GRID_a + GRID_l + GRID_v + GRID_ve + GRID_data + GRID_pro + GRID_aux + GRID_ww + GRID_cs + GRID_hs + GRID_cdata + GRID_cre |
GRID_pro0_kW |
Nominal grid electricity requirements for industrial processes |
GRID_pro_MWhyr |
Grid electricity requirements for industrial processes |
GRID_v0_kW |
Nominal grid electricity consumption for electric vehicles |
GRID_v_MWhyr |
Grid electricity requirements for electric vehicles |
GRID_ve0_kW |
Nominal grid electricity consumption for ventilatioon |
GRID_ve_MWhyr |
Grid electricity requirements for ventilatioon |
GRID_ww0_kW |
Nominal grid electricity requirements for hot water supply |
GRID_ww_MWhyr |
Grid electricity requirements for hot water supply |
Name |
Unique building ID. It must start with a letter. |
NG_hs0_kW |
Nominal NG requirement for space heating supply |
NG_hs_MWhyr |
NG requirement for space heating supply |
NG_ww0_kW |
Nominal NG requirement for hotwater supply |
NG_ww_MWhyr |
NG requirement for hotwater supply |
OIL_hs0_kW |
Nominal OIL requirement for space heating supply |
OIL_hs_MWhyr |
OIL requirement for space heating supply |
OIL_ww0_kW |
Nominal OIL requirement for hotwater supply |
OIL_ww_MWhyr |
OIL requirement for hotwater supply |
people0 |
Nominal occupancy |
PV0_kW |
Nominal PV electricity consumption |
PV_MWhyr |
PV electricity consumption |
QC_sys0_kW |
Nominal Total system cooling demand. |
QC_sys_MWhyr |
Total system cooling demand, QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys |
Qcdata0_kW |
Nominal Data centre cooling demand. |
Qcdata_MWhyr |
Data centre cooling demand |
Qcdata_sys0_kW |
Nominal end-use data center cooling demand |
Qcdata_sys_MWhyr |
End-use data center cooling demand |
Qcpro_sys0_kW |
Nominal process cooling demand. |
Qcpro_sys_MWhyr |
Yearly processes cooling demand. |
Qcre0_kW |
Nominal Refrigeration cooling demand. |
Qcre_MWhyr |
Refrigeration cooling demand for the system |
Qcre_sys0_kW |
|
Qcre_sys_MWhyr |
End-use refrigeration demand |
Qcs0_kW |
Nominal Total cooling demand. |
Qcs_dis_ls0_kW |
Nominal Cooling distribution losses. |
Qcs_dis_ls_MWhyr |
Cooling distribution losses |
Qcs_em_ls0_kW |
Nominal Cooling emission losses. |
Qcs_em_ls_MWhyr |
Cooling emission losses |
Qcs_lat_ahu0_kW |
Nominal AHU latent cooling demand. |
Qcs_lat_ahu_MWhyr |
AHU latent cooling demand |
Qcs_lat_aru0_kW |
Nominal ARU latent cooling demand. |
Qcs_lat_aru_MWhyr |
ARU latent cooling demand |
Qcs_lat_sys0_kW |
Nominal System latent cooling demand. |
Qcs_lat_sys_MWhyr |
System latent cooling demand |
Qcs_MWhyr |
Total cooling demand |
Qcs_sen_ahu0_kW |
Nominal AHU system cooling demand. |
Qcs_sen_ahu_MWhyr |
Sensible cooling demand in AHU |
Qcs_sen_aru0_kW |
Nominal ARU system cooling demand. |
Qcs_sen_aru_MWhyr |
ARU system cooling demand |
Qcs_sen_scu0_kW |
Nominal SCU system cooling demand. |
Qcs_sen_scu_MWhyr |
SCU system cooling demand |
Qcs_sen_sys0_kW |
Nominal Sensible system cooling demand. |
Qcs_sen_sys_MWhyr |
Total sensible cooling demand |
Qcs_sys0_kW |
Nominal end-use space cooling demand |
Qcs_sys_ahu0_kW |
Nominal AHU system cooling demand. |
Qcs_sys_ahu_MWhyr |
AHU system cooling demand |
Qcs_sys_aru0_kW |
Nominal ARU system cooling demand. |
Qcs_sys_aru_MWhyr |
ARU system cooling demand |
Qcs_sys_MWhyr |
End-use space cooling demand, Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls |
Qcs_sys_scu0_kW |
Nominal SCU system cooling demand. |
Qcs_sys_scu_MWhyr |
SCU system cooling demand |
QH_sys0_kW |
Nominal total building heating demand. |
QH_sys_MWhyr |
Total building heating demand |
Qhpro_sys0_kW |
Nominal process heating demand. |
Qhpro_sys_MWhyr |
Yearly processes heating demand. |
Qhs0_kW |
Nominal space heating demand. |
Qhs_dis_ls0_kW |
Nominal Heating system distribution losses. |
Qhs_dis_ls_MWhyr |
Heating system distribution losses |
Qhs_em_ls0_kW |
Nominal Heating emission losses. |
Qhs_em_ls_MWhyr |
Heating system emission losses |
Qhs_lat_ahu0_kW |
Nominal AHU latent heating demand. |
Qhs_lat_ahu_MWhyr |
AHU latent heating demand |
Qhs_lat_aru0_kW |
Nominal ARU latent heating demand. |
Qhs_lat_aru_MWhyr |
ARU latent heating demand |
Qhs_lat_sys0_kW |
Nominal System latent heating demand. |
Qhs_lat_sys_MWhyr |
System latent heating demand |
Qhs_MWhyr |
Total space heating demand. |
Qhs_sen_ahu0_kW |
Nominal AHU sensible heating demand. |
Qhs_sen_ahu_MWhyr |
AHU sensible heating demand |
Qhs_sen_aru0_kW |
ARU sensible heating demand |
Qhs_sen_aru_MWhyr |
ARU sensible heating demand |
Qhs_sen_shu0_kW |
Nominal SHU sensible heating demand. |
Qhs_sen_shu_MWhyr |
SHU sensible heating demand |
Qhs_sen_sys0_kW |
Nominal HVAC systems sensible heating demand. |
Qhs_sen_sys_MWhyr |
SHU sensible heating demand |
Qhs_sys0_kW |
Nominal end-use space heating demand |
Qhs_sys_ahu0_kW |
Nominal AHU sensible heating demand. |
Qhs_sys_ahu_MWhyr |
AHU system heating demand |
Qhs_sys_aru0_kW |
Nominal ARU sensible heating demand. |
Qhs_sys_aru_MWhyr |
ARU sensible heating demand |
Qhs_sys_MWhyr |
End-use space heating demand, Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls |
Qhs_sys_shu0_kW |
Nominal SHU sensible heating demand. |
Qhs_sys_shu_MWhyr |
SHU sensible heating demand |
Qww0_kW |
Nominal DHW heating demand. |
Qww_MWhyr |
DHW heating demand |
Qww_sys0_kW |
Nominal end-use hotwater demand |
Qww_sys_MWhyr |
End-use hotwater demand |
SOLAR_hs0_kW |
Nominal solar thermal energy requirement for space heating supply |
SOLAR_hs_MWhyr |
Solar thermal energy requirement for space heating supply |
SOLAR_ww0_kW |
Nominal solar thermal energy requirement for hotwater supply |
SOLAR_ww_MWhyr |
Solar thermal energy requirement for hotwater supply |
WOOD_hs0_kW |
Nominal WOOD requirement for space heating supply |
WOOD_hs_MWhyr |
WOOD requirement for space heating supply |
WOOD_ww0_kW |
Nominal WOOD requirement for hotwater supply |
WOOD_ww_MWhyr |
WOOD requirement for hotwater supply |
get_radiation_building¶
path: outputs/data/solar-radiation/{building}_radiation.csv
The following file is used by these scripts: demand
, photovoltaic
, photovoltaic_thermal
, solar_collector
Variable | Description |
---|---|
Date |
Date and time in hourly steps |
roofs_top_kW |
solar incident on the roof tops |
roofs_top_m2 |
roof top area |
walls_east_kW |
solar incident on the east facing facades excluding windows |
walls_east_m2 |
area of the east facing facades excluding windows |
walls_north_kW |
solar incident on the north facing facades excluding windows |
walls_north_m2 |
area of the north facing facades excluding windows |
walls_south_kW |
solar incident on the south facing facades excluding windows |
walls_south_m2 |
area of the south facing facades excluding windows |
walls_west_kW |
solar incident on the west facing facades excluding windows |
walls_west_m2 |
area of the south facing facades excluding windows |
windows_east_kW |
solar incident on windows on the south facing facades |
windows_east_m2 |
window area on the east facing facades |
windows_north_kW |
solar incident on windows on the south facing facades |
windows_north_m2 |
window area on the north facing facades |
windows_south_kW |
solar incident on windows on the south facing facades |
windows_south_m2 |
window area on the south facing facades |
windows_west_kW |
solar incident on windows on the west facing facades |
windows_west_m2 |
window area on the west facing facades |
get_radiation_building_sensors¶
path: outputs/data/solar-radiation/B001_insolation_Whm2.json
The following file is used by these scripts: demand
, photovoltaic
, photovoltaic_thermal
, solar_collector
Variable | Description |
---|---|
srf0 |
TODO |
get_radiation_materials¶
path: outputs/data/solar-radiation/buidling_materials.csv
The following file is used by these scripts:
Variable | Description |
---|---|
G_win |
Solar heat gain coefficient. Defined according to ISO 13790. |
Name |
Unique building ID. It must start with a letter. |
r_roof |
Reflectance in the Red spectrum. Defined according Radiance. (long-wave) |
r_wall |
Reflectance in the Red spectrum. Defined according Radiance. (long-wave) |
type_base |
Basement floor construction assembly (relates to “code” in ENVELOPE assemblies) |
type_floor |
Internal floor construction assembly (relates to “code” in ENVELOPE assemblies) |
type_roof |
Roof construction assembly (relates to “code” in ENVELOPE assemblies) |
type_wall |
External wall construction assembly (relates to “code” in ENVELOPE assemblies) |
type_win |
Window assembly (relates to “code” in ENVELOPE assemblies) |
get_radiation_metadata¶
path: outputs/data/solar-radiation/B001_geometry.csv
The following file is used by these scripts: demand
, photovoltaic
, photovoltaic_thermal
, solar_collector
Variable | Description |
---|---|
AREA_m2 |
Surface area. |
BUILDING |
Unique building ID. It must start with a letter. |
intersection |
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
orientation |
Orientation of the surface (north/east/south/west/top) |
SURFACE |
Unique surface ID for each building exterior surface. |
TYPE |
Surface typology. |
Xcoor |
Describes the position of the x vector. |
Xdir |
Directional scalar of the x vector. |
Ycoor |
Describes the position of the y vector. |
Ydir |
Directional scalar of the y vector. |
Zcoor |
Describes the position of the z vector. |
Zdir |
Directional scalar of the z vector. |
get_schedule_model_file¶
path: outputs/data/occupancy/B001.csv
The following file is used by these scripts: demand
Variable | Description |
---|---|
DATE |
Time stamp for each day of the year ascending in hourly intervals |
Ea_W |
Electrical load due to processes |
Ed_W |
Electrical load due to servers/data centers |
El_W |
Electrical load due to lighting |
Epro_W |
Electrical load due to processes |
people_p |
Number of people in the building |
Qcpro_W |
Process cooling load |
Qcre_W |
Cooling load due to cool room refrigeration |
Qhpro_W |
Process heat load |
Qs_W |
Sensible heat load of people |
Tcs_set_C |
Set point temperature of space cooling system |
Ths_set_C |
Set point temperature of space heating system |
Ve_lps |
Ventilation rate |
Vw_lph |
Fresh water consumption (includes cold and hot water) |
Vww_lph |
Domestic hot water consumption |
X_gh |
Moisture released by occupants |
get_sewage_heat_potential¶
path: outputs/data/potentials/Sewage_heat_potential.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
mww_zone_kWperC |
heat capacity of total sewage in a zone |
Qsw_kW |
heat extracted from sewage flows |
T_in_HP_C |
Inlet temperature of the sweage heapump |
T_in_sw_C |
Inlet temperature of sewage flows |
T_out_HP_C |
Outlet temperature of the sewage heatpump |
T_out_sw_C |
Outlet temperature of sewage flows |
Ts_C |
Average temperature of sewage flows |
get_thermal_demand_csv_file¶
path: outputs/data/thermal-network/DH__thermal_demand_per_building_W.csv
The following file is used by these scripts:
Variable | Description |
---|---|
B01 |
Thermal demand for building B01 at each simulation time step |
get_thermal_network_edge_list_file¶
path: outputs/data/thermal-network/DH__metadata_edges.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
D_int_m |
Internal pipe diameter for the nominal diameter |
length_m |
Length of each pipe in the network |
Name |
Unique network pipe ID. |
Pipe_DN |
Nominal pipe diameter (e.g. DN100 refers to pipes of approx. 100 mm in diameter) |
Type_mat |
Material of the pipes |
get_thermal_network_edge_node_matrix_file¶
path: outputs/data/thermal-network/{network_type}__EdgeNode.csv
The following file is used by these scripts: thermal_network
Variable | Description |
---|---|
NODE |
Names of the nodes in the network |
PIPE0 |
Indicates the direction of flow of PIPE0 with respect to each node NODEn: if equal to PIPE0 and NODEn are not connected / if equal to 1 PIPE0 enters NODEn / if equal to -1 PIPE0 leaves NODEn |
get_thermal_network_layout_massflow_edges_file¶
path: outputs/data/thermal-network/DH__massflow_edges_kgs.csv
The following file is used by these scripts:
Variable | Description |
---|---|
PIPE0 |
Mass flow rate in pipe PIPE0 at each time step |
get_thermal_network_layout_massflow_nodes_file¶
path: outputs/data/thermal-network/DH__massflow_nodes_kgs.csv
The following file is used by these scripts:
Variable | Description |
---|---|
NODE0 |
Mass flow rate in node NODE0 at each time step |
get_thermal_network_node_types_csv_file¶
path: outputs/data/thermal-network/DH__metadata_nodes.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Building |
Unique building ID. It must start with a letter. |
Name |
Unique network node ID. |
Type |
Type of node: “PLANT” / “CONSUMER” / “NONE” (if it is neither) |
get_thermal_network_plant_heat_requirement_file¶
path: outputs/data/thermal-network/DH__plant_thermal_load_kW.csv
The following file is used by these scripts:
Variable | Description |
---|---|
thermal_load_kW |
Thermal load supplied by the plant at each time step |
get_thermal_network_pressure_losses_edges_file¶
path: outputs/data/thermal-network/DH__pressure_losses_edges_kW.csv
The following file is used by these scripts:
Variable | Description |
---|---|
PIPE0 |
Pressure losses at pipe PIPE0 at each time step |
get_thermal_network_substation_ploss_file¶
path: outputs/data/thermal-network/DH__pumping_load_due_to_substations_kW.csv
The following file is used by these scripts:
Variable | Description |
---|---|
B01 |
Pumping load at building substation B01 for each timestep |
get_thermal_network_velocity_edges_file¶
path: outputs/data/thermal-network/DH__velocity_edges_mpers.csv
The following file is used by these scripts:
Variable | Description |
---|---|
PIPE0 |
Flow velocity of heating/cooling medium in pipe PIPE0 |
get_total_demand¶
path: outputs/data/demand/Total_demand.csv
The following file is used by these scripts: decentralized
, emissions
, network_layout
, system_costs
, optimization
, sewage_potential
, thermal_network
Variable | Description |
---|---|
Af_m2 |
Conditioned floor area (heated/cooled) |
Aocc_m2 |
Occupied floor area (heated/cooled) |
Aroof_m2 |
Roof area |
COAL_hs0_kW |
Nominal Coal requirement for space heating supply |
COAL_hs_MWhyr |
Coal requirement for space heating supply |
COAL_ww0_kW |
Nominal Coal requirement for hotwater supply |
COAL_ww_MWhyr |
Coal requirement for hotwater supply |
DC_cdata0_kW |
Nominal district cooling for final data center cooling demand |
DC_cdata_MWhyr |
District cooling for data center cooling demand |
DC_cre0_kW |
Nominal district cooling for refrigeration demand |
DC_cre_MWhyr |
District cooling for refrigeration demand |
DC_cs0_kW |
Nominal district cooling for space cooling demand |
DC_cs_MWhyr |
Energy consumption of space cooling system (if supplied by District Cooling), DC_cs = Qcs_sys / eff_cs |
DH_hs0_kW |
Nominal energy requirement by district heating (space heating supply) |
DH_hs_MWhyr |
Energy requirement by district heating (space heating supply) |
DH_ww0_kW |
Nominal Energy requirement by district heating (hotwater supply) |
DH_ww_MWhyr |
Energy requirement by district heating (hotwater supply) |
E_cdata0_kW |
Nominal Data centre cooling specific electricity consumption. |
E_cdata_MWhyr |
Electricity consumption due to data center cooling |
E_cre0_kW |
Nominal Refrigeration system electricity consumption. |
E_cre_MWhyr |
Electricity consumption due to refrigeration |
E_cs0_kW |
Nominal Cooling system electricity consumption. |
E_cs_MWhyr |
Energy consumption of cooling system (if supplied by electricity grid), E_cs = Qcs_sys / eff_cs |
E_hs0_kW |
Nominal Heating system electricity consumption. |
E_hs_MWhyr |
Electricity consumption due to space heating |
E_sys0_kW |
Nominal end-use electricity demand |
E_sys_MWhyr |
End-use total electricity consumption, E_sys = Eve + Ea + El + Edata + Epro + Eaux + Ev |
E_ww0_kW |
Nominal Domestic hot water electricity consumption. |
E_ww_MWhyr |
Electricity consumption due to hot water |
Ea0_kW |
Nominal end-use electricity for appliances |
Ea_MWhyr |
End-use electricity for appliances |
Eal0_kW |
Nominal Total net electricity for all sources and sinks. |
Eal_MWhyr |
End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W |
Eaux0_kW |
Nominal Auxiliary electricity consumption. |
Eaux_MWhyr |
End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux |
Edata0_kW |
Nominal Data centre electricity consumption. |
Edata_MWhyr |
Electricity consumption for data centers |
El0_kW |
Nominal end-use electricity for lights |
El_MWhyr |
End-use electricity for lights |
Epro0_kW |
Nominal Industrial processes electricity consumption. |
Epro_MWhyr |
Electricity supplied to industrial processes |
Ev0_kW |
Nominal end-use electricity for electric vehicles |
Ev_MWhyr |
End-use electricity for electric vehicles |
Eve0_kW |
Nominal end-use electricity for ventilation |
Eve_MWhyr |
End-use electricity for ventilation |
GFA_m2 |
Gross floor area |
GRID0_kW |
Nominal Grid electricity consumption |
GRID_a0_kW |
Nominal grid electricity requirements for appliances |
GRID_a_MWhyr |
Grid electricity requirements for appliances |
GRID_aux0_kW |
Nominal grid electricity requirements for auxiliary loads |
GRID_aux_MWhyr |
Grid electricity requirements for auxiliary loads |
GRID_cdata0_kW |
Nominal grid electricity requirements for servers cooling |
GRID_cdata_MWhyr |
Grid electricity requirements for servers cooling |
GRID_cre0_kW |
Nominal grid electricity requirements for refrigeration |
GRID_cre_MWhyr |
Grid electricity requirements for refrigeration |
GRID_cs0_kW |
Nominal grid electricity requirements for space cooling |
GRID_cs_MWhyr |
Grid electricity requirements for space cooling |
GRID_data0_kW |
Nominal grid electricity requirements for servers |
GRID_data_MWhyr |
Grid electricity requirements for servers |
GRID_hs0_kW |
Nominal grid electricity requirements for space heating |
GRID_hs_MWhyr |
Grid electricity requirements for space heating |
GRID_l0_kW |
Nominal grid electricity consumption for lights |
GRID_l_MWhyr |
Grid electricity requirements for lights |
GRID_MWhyr |
Grid electricity consumption, GRID_a + GRID_l + GRID_v + GRID_ve + GRID_data + GRID_pro + GRID_aux + GRID_ww + GRID_cs + GRID_hs + GRID_cdata + GRID_cre |
GRID_pro0_kW |
Nominal grid electricity requirements for industrial processes |
GRID_pro_MWhyr |
Grid electricity requirements for industrial processes |
GRID_v0_kW |
Nominal grid electricity consumption for electric vehicles |
GRID_v_MWhyr |
Grid electricity requirements for electric vehicles |
GRID_ve0_kW |
Nominal grid electricity consumption for ventilation |
GRID_ve_MWhyr |
Grid electricity requirements for ventilation |
GRID_ww0_kW |
Nominal grid electricity requirements for hot water supply |
GRID_ww_MWhyr |
Grid electricity requirements for hot water supply |
Name |
Unique building ID. It must start with a letter. |
NG_hs0_kW |
Nominal NG requirement for space heating supply |
NG_hs_MWhyr |
NG requirement for space heating supply |
NG_ww0_kW |
Nominal NG requirement for hotwater supply |
NG_ww_MWhyr |
NG requirement for hotwater supply |
OIL_hs0_kW |
Nominal OIL requirement for space heating supply |
OIL_hs_MWhyr |
OIL requirement for space heating supply |
OIL_ww0_kW |
Nominal OIL requirement for hotwater supply |
OIL_ww_MWhyr |
OIL requirement for hotwater supply |
people0 |
Nominal occupancy |
PV0_kW |
Nominal PV electricity consumption |
PV_MWhyr |
PV electricity consumption |
QC_sys0_kW |
Nominal Total system cooling demand. |
QC_sys_MWhyr |
Total energy demand for cooling, QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys |
Qcdata0_kW |
Nominal Data centre cooling demand. |
Qcdata_MWhyr |
Data centre cooling demand |
Qcdata_sys0_kW |
Nominal end-use data center cooling demand |
Qcdata_sys_MWhyr |
End-use data center cooling demand |
Qcpro_sys0_kW |
Nominal process cooling demand. |
Qcpro_sys_MWhyr |
Yearly processes cooling demand. |
Qcre0_kW |
Nominal Refrigeration cooling demand. |
Qcre_MWhyr |
Refrigeration cooling demand for the system |
Qcre_sys0_kW |
|
Qcre_sys_MWhyr |
End-use refrigeration demand |
Qcs0_kW |
Nominal Total cooling demand. |
Qcs_dis_ls0_kW |
Nominal Cooling distribution losses. |
Qcs_dis_ls_MWhyr |
Cooling distribution losses |
Qcs_em_ls0_kW |
Nominal Cooling emission losses. |
Qcs_em_ls_MWhyr |
Cooling emission losses |
Qcs_lat_ahu0_kW |
Nominal AHU latent cooling demand. |
Qcs_lat_ahu_MWhyr |
AHU latent cooling demand |
Qcs_lat_aru0_kW |
Nominal ARU latent cooling demand. |
Qcs_lat_aru_MWhyr |
ARU latent cooling demand |
Qcs_lat_sys0_kW |
Nominal System latent cooling demand. |
Qcs_lat_sys_MWhyr |
Latent cooling demand |
Qcs_MWhyr |
Total cooling demand |
Qcs_sen_ahu0_kW |
Nominal AHU system cooling demand. |
Qcs_sen_ahu_MWhyr |
AHU system cooling demand |
Qcs_sen_aru0_kW |
Nominal ARU system cooling demand. |
Qcs_sen_aru_MWhyr |
ARU system cooling demand |
Qcs_sen_scu0_kW |
Nominal SCU system cooling demand. |
Qcs_sen_scu_MWhyr |
SCU system cooling demand |
Qcs_sen_sys0_kW |
Nominal Sensible system cooling demand. |
Qcs_sen_sys_MWhyr |
Sensible system cooling demand |
Qcs_sys0_kW |
Nominal end-use space cooling demand |
Qcs_sys_ahu0_kW |
Nominal AHU system cooling demand. |
Qcs_sys_ahu_MWhyr |
AHU system cooling demand |
Qcs_sys_aru0_kW |
Nominal ARU system cooling demand. |
Qcs_sys_aru_MWhyr |
ARU system cooling demand |
Qcs_sys_MWhyr |
End-use space cooling demand, Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls |
Qcs_sys_scu0_kW |
Nominal SCU system cooling demand. |
Qcs_sys_scu_MWhyr |
SCU system cooling demand |
QH_sys0_kW |
Nominal total building heating demand. |
QH_sys_MWhyr |
Total energy demand for heating |
Qhpro_sys0_kW |
Nominal process heating demand. |
Qhpro_sys_MWhyr |
Yearly processes heating demand. |
Qhs0_kW |
Nominal Total heating demand. |
Qhs_dis_ls0_kW |
Nominal Heating system distribution losses. |
Qhs_dis_ls_MWhyr |
Heating system distribution losses |
Qhs_em_ls0_kW |
Nominal Heating emission losses. |
Qhs_em_ls_MWhyr |
Heating system emission losses |
Qhs_lat_ahu0_kW |
Nominal AHU latent heating demand. |
Qhs_lat_ahu_MWhyr |
AHU latent heating demand |
Qhs_lat_aru0_kW |
Nominal ARU latent heating demand. |
Qhs_lat_aru_MWhyr |
ARU latent heating demand |
Qhs_lat_sys0_kW |
Nominal System latent heating demand. |
Qhs_lat_sys_MWhyr |
System latent heating demand |
Qhs_MWhyr |
Total heating demand |
Qhs_sen_ahu0_kW |
Nominal AHU sensible heating demand. |
Qhs_sen_ahu_MWhyr |
Sensible heating demand in AHU |
Qhs_sen_aru0_kW |
ARU sensible heating demand |
Qhs_sen_aru_MWhyr |
ARU sensible heating demand |
Qhs_sen_shu0_kW |
Nominal SHU sensible heating demand. |
Qhs_sen_shu_MWhyr |
SHU sensible heating demand |
Qhs_sen_sys0_kW |
Nominal HVAC systems sensible heating demand. |
Qhs_sen_sys_MWhyr |
Sensible heating demand |
Qhs_sys0_kW |
Nominal end-use space heating demand |
Qhs_sys_ahu0_kW |
Nominal AHU sensible heating demand. |
Qhs_sys_ahu_MWhyr |
AHU system heating demand |
Qhs_sys_aru0_kW |
Nominal ARU sensible heating demand. |
Qhs_sys_aru_MWhyr |
ARU sensible heating demand |
Qhs_sys_MWhyr |
End-use space heating demand, Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls |
Qhs_sys_shu0_kW |
Nominal SHU sensible heating demand. |
Qhs_sys_shu_MWhyr |
SHU sensible heating demand |
Qww0_kW |
Nominal DHW heating demand. |
Qww_MWhyr |
DHW heating demand |
Qww_sys0_kW |
Nominal end-use hotwater demand |
Qww_sys_MWhyr |
End-use hotwater demand |
SOLAR_hs0_kW |
Nominal solar thermal energy requirement for space heating supply |
SOLAR_hs_MWhyr |
Solar thermal energy requirement for space heating supply |
SOLAR_ww0_kW |
Nominal solar thermal energy requirement for hotwater supply |
SOLAR_ww_MWhyr |
Solar thermal energy requirement for hotwater supply |
WOOD_hs0_kW |
Nominal WOOD requirement for space heating supply |
WOOD_hs_MWhyr |
WOOD requirement for space heating supply |
WOOD_ww0_kW |
Nominal WOOD requirement for hotwater supply |
WOOD_ww_MWhyr |
WOOD requirement for hotwater supply |
get_water_body_potential¶
path: outputs/data/potentials/Water_body_potential.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
QLake_kW |
thermal potential from water body |
Ts_C |
average temperature of the water body |
get_weather_file¶
path: inputs/weather/weather.epw
The following file is used by these scripts: decentralized
, demand
, optimization
, photovoltaic
, photovoltaic_thermal
, radiation
, schedule_maker
, shallow_geothermal_potential
, solar_collector
, thermal_network
Variable | Description |
---|---|
aerosol_opt_thousandths (index = 29) |
TODO |
Albedo (index = 32) |
TODO |
atmos_Pa (index = 9) |
TODO |
ceiling_hgt_m (index = 25) |
TODO |
datasource (index = 5) |
TODO |
day (index = 2) |
TODO |
days_last_snow (index = 31) |
TODO |
dewpoint_C (index = 7) |
TODO |
difhorillum_lux (index = 18) |
TODO |
difhorrad_Whm2 (index = 15) |
TODO |
dirnorillum_lux (index = 17) |
TODO |
dirnorrad_Whm2 (index = 14) |
TODO |
drybulb_C (index = 6) |
TODO |
extdirrad_Whm2 (index = 11) |
TODO |
exthorrad_Whm2 (index = 10) |
TODO |
glohorillum_lux (index = 16) |
TODO |
glohorrad_Whm2 (index = 13) |
TODO |
horirsky_Whm2 (index = 12) |
TODO |
hour (index = 3) |
TODO |
liq_precip_depth_mm (index = 33) |
TODO |
liq_precip_rate_Hour (index = 34) |
TODO |
minute (index = 4) |
TODO |
month (index = 1) |
TODO |
opaqskycvr_tenths (index = 23) |
TODO |
precip_wtr_mm (index = 28) |
TODO |
presweathcodes (index = 27) |
TODO |
presweathobs (index = 26) |
TODO |
relhum_percent (index = 8) |
TODO |
snowdepth_cm (index = 30) |
TODO |
totskycvr_tenths (index = 22) |
TODO |
visibility_km (index = 24) |
TODO |
winddir_deg (index = 20) |
TODO |
windspd_ms (index = 21) |
TODO |
year (index = 0) |
TODO |
zenlum_lux (index = 19) |
TODO |
PV_metadata_results¶
path: outputs/data/potentials/solar/B001_PV_sensors.csv
The following file is used by these scripts:
Variable | Description |
---|---|
area_installed_module_m2 |
The area of the building suface covered by one solar panel |
AREA_m2 |
Surface area. |
array_spacing_m |
Spacing between solar arrays. |
B_deg |
Tilt angle of the installed solar panels |
BUILDING |
Unique building ID. It must start with a letter. |
CATB |
Category according to the tilt angle of the panel |
CATGB |
Category according to the annual radiation on the panel surface |
CATteta_z |
Category according to the surface azimuth of the panel |
intersection |
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
orientation |
Orientation of the surface (north/east/south/west/top) |
SURFACE |
Unique surface ID for each building exterior surface. |
surface |
Unique surface ID for each building exterior surface. |
surface_azimuth_deg |
Azimuth angle of the panel surface e.g. south facing = 180 deg |
tilt_deg |
Tilt angle of roof or walls |
total_rad_Whm2 |
Total radiatiative potential of a given surfaces area. |
TYPE |
Surface typology. |
type_orientation |
Concatenated surface type and orientation. |
Xcoor |
Describes the position of the x vector. |
Xdir |
Directional scalar of the x vector. |
Ycoor |
Describes the position of the y vector. |
Ydir |
Directional scalar of the y vector. |
Zcoor |
Describes the position of the z vector. |
Zdir |
Directional scalar of the z vector. |
PV_results¶
path: outputs/data/potentials/solar/B001_PV.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Area_PV_m2 |
Total area of investigated collector. |
Date |
Date and time in hourly steps. |
E_PV_gen_kWh |
Total electricity generated by the collector. |
PV_roofs_top_E_kWh |
Electricity production from photovoltaic panels on roof tops |
PV_roofs_top_m2 |
Collector surface area on roof tops. |
PV_walls_east_E_kWh |
Electricity production from photovoltaic panels on east facades |
PV_walls_east_m2 |
Collector surface area on east facades. |
PV_walls_north_E_kWh |
Electricity production from photovoltaic panels on north facades |
PV_walls_north_m2 |
Collector surface area on north facades. |
PV_walls_south_E_kWh |
Electricity production from photovoltaic panels on south facades |
PV_walls_south_m2 |
Collector surface area on south facades. |
PV_walls_west_E_kWh |
Electricity production from photovoltaic panels on west facades |
PV_walls_west_m2 |
West facing wall collector surface area. |
radiation_kWh |
Total radiatiative potential. |
PV_total_buildings¶
path: outputs/data/potentials/solar/PV_total_buildings.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Area_PV_m2 |
Total area of investigated collector. |
E_PV_gen_kWh |
Total electricity generated by the collector. |
Name |
Unique building ID. It must start with a letter. |
PV_roofs_top_E_kWh |
Electricity production from photovoltaic panels on roof tops |
PV_roofs_top_m2 |
Collector surface area on roof tops. |
PV_walls_east_E_kWh |
Electricity production from photovoltaic panels on east facades |
PV_walls_east_m2 |
Collector surface area on east facades. |
PV_walls_north_E_kWh |
Electricity production from photovoltaic panels on north facades |
PV_walls_north_m2 |
Collector surface area on north facades. |
PV_walls_south_E_kWh |
Electricity production from photovoltaic panels on south facades |
PV_walls_south_m2 |
Collector surface area on south facades. |
PV_walls_west_E_kWh |
Electricity production from photovoltaic panels on west facades |
PV_walls_west_m2 |
West facing wall collector surface area. |
radiation_kWh |
Total radiatiative potential. |
PV_totals¶
path: outputs/data/potentials/solar/PV_total.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Area_PV_m2 |
Total area of investigated collector. |
Date |
Date and time in hourly steps. |
E_PV_gen_kWh |
Total electricity generated by the collector. |
PV_roofs_top_E_kWh |
Electricity production from photovoltaic panels on roof tops |
PV_roofs_top_m2 |
Collector surface area on roof tops. |
PV_walls_east_E_kWh |
Electricity production from photovoltaic panels on east facades |
PV_walls_east_m2 |
Collector surface area on east facades. |
PV_walls_north_E_kWh |
Electricity production from photovoltaic panels on north facades |
PV_walls_north_m2 |
Collector surface area on north facades. |
PV_walls_south_E_kWh |
Electricity production from photovoltaic panels on south facades |
PV_walls_south_m2 |
Collector surface area on south facades. |
PV_walls_west_E_kWh |
Electricity production from photovoltaic panels on west facades |
PV_walls_west_m2 |
West facing wall collector surface area. |
radiation_kWh |
Total radiatiative potential. |
PVT_metadata_results¶
path: outputs/data/potentials/solar/B001_PVT_sensors.csv
The following file is used by these scripts:
Variable | Description |
---|---|
area_installed_module_m2 |
The area of the building suface covered by one solar panel |
AREA_m2 |
Surface area. |
array_spacing_m |
Spacing between solar arrays. |
B_deg |
Tilt angle of the installed solar panels |
BUILDING |
Unique building ID. It must start with a letter. |
CATB |
Category according to the tilt angle of the panel |
CATGB |
Category according to the annual radiation on the panel surface |
CATteta_z |
Category according to the surface azimuth of the panel |
intersection |
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
orientation |
Orientation of the surface (north/east/south/west/top) |
SURFACE |
Unique surface ID for each building exterior surface. |
surface |
Unique surface ID for each building exterior surface. |
surface_azimuth_deg |
Azimuth angle of the panel surface e.g. south facing = 180 deg |
tilt_deg |
Tilt angle of roof or walls |
total_rad_Whm2 |
Total radiatiative potential of a given surfaces area. |
TYPE |
Surface typology. |
type_orientation |
Concatenated surface type and orientation. |
Xcoor |
Describes the position of the x vector. |
Xdir |
Directional scalar of the x vector. |
Ycoor |
Describes the position of the y vector. |
Ydir |
Directional scalar of the y vector. |
Zcoor |
Describes the position of the z vector. |
Zdir |
Directional scalar of the z vector. |
PVT_results¶
path: outputs/data/potentials/solar/B001_PVT.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Area_PVT_m2 |
Total area of investigated collector. |
Date |
Date and time in hourly steps. |
E_PVT_gen_kWh |
Total electricity generated by the collector. |
Eaux_PVT_kWh |
Auxiliary electricity consumed by the collector. |
mcp_PVT_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
PVT_roofs_top_E_kWh |
Electricity production from photovoltaic-thermal panels on roof tops |
PVT_roofs_top_m2 |
Collector surface area on roof tops. |
PVT_roofs_top_Q_kWh |
Heat production from photovoltaic-thermal panels on roof tops |
PVT_walls_east_E_kWh |
Electricity production from photovoltaic-thermal panels on east facades |
PVT_walls_east_m2 |
Collector surface area on east facades. |
PVT_walls_east_Q_kWh |
Heat production from photovoltaic-thermal panels on east facades |
PVT_walls_north_E_kWh |
Electricity production from photovoltaic-thermal panels on north facades |
PVT_walls_north_m2 |
Collector surface area on north facades. |
PVT_walls_north_Q_kWh |
Heat production from photovoltaic-thermal panels on north facades |
PVT_walls_south_E_kWh |
Electricity production from photovoltaic-thermal panels on south facades |
PVT_walls_south_m2 |
Collector surface area on south facades. |
PVT_walls_south_Q_kWh |
Heat production from photovoltaic-thermal panels on south facades |
PVT_walls_west_E_kWh |
Electricity production from photovoltaic-thermal panels on west facades |
PVT_walls_west_m2 |
West facing wall collector surface area. |
PVT_walls_west_Q_kWh |
Heat production from photovoltaic-thermal panels on west facades |
Q_PVT_gen_kWh |
Total heat generated by the collector. |
Q_PVT_l_kWh |
Collector heat loss. |
radiation_kWh |
Total radiatiative potential. |
T_PVT_re_C |
Collector hot water return temperature. |
T_PVT_sup_C |
Collector heating supply temperature. |
PVT_total_buildings¶
path: outputs/data/potentials/solar/PVT_total_buildings.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Area_PVT_m2 |
Total area of investigated collector. |
E_PVT_gen_kWh |
Total electricity generated by the collector. |
Eaux_PVT_kWh |
Auxiliary electricity consumed by the collector. |
Name |
Unique building ID. |
PVT_roofs_top_E_kWh |
Electricity production from photovoltaic-thermal panels on roof tops |
PVT_roofs_top_m2 |
Collector surface area on roof tops. |
PVT_roofs_top_Q_kWh |
Heat production from photovoltaic-thermal panels on roof tops |
PVT_walls_east_E_kWh |
Electricity production from photovoltaic-thermal panels on east facades |
PVT_walls_east_m2 |
Collector surface area on east facades. |
PVT_walls_east_Q_kWh |
Heat production from photovoltaic-thermal panels on east facades |
PVT_walls_north_E_kWh |
Electricity production from photovoltaic-thermal panels on north facades |
PVT_walls_north_m2 |
Collector surface area on north facades. |
PVT_walls_north_Q_kWh |
Heat production from photovoltaic-thermal panels on north facades |
PVT_walls_south_E_kWh |
Electricity production from photovoltaic-thermal panels on south facades |
PVT_walls_south_m2 |
Collector surface area on south facades. |
PVT_walls_south_Q_kWh |
Heat production from photovoltaic-thermal panels on south facades |
PVT_walls_west_E_kWh |
Electricity production from photovoltaic-thermal panels on west facades |
PVT_walls_west_m2 |
West facing wall collector surface area. |
PVT_walls_west_Q_kWh |
Heat production from photovoltaic-thermal panels on west facades |
Q_PVT_gen_kWh |
Total heat generated by the collector. |
Q_PVT_l_kWh |
Collector heat loss. |
radiation_kWh |
Total radiatiative potential. |
PVT_totals¶
path: outputs/data/potentials/solar/PVT_total.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Area_PVT_m2 |
Total area of investigated collector. |
Date |
Date and time in hourly steps. |
E_PVT_gen_kWh |
Total electricity generated by the collector. |
Eaux_PVT_kWh |
Auxiliary electricity consumed by the collector. |
mcp_PVT_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
PVT_roofs_top_E_kWh |
Electricity production from photovoltaic-thermal panels on roof tops |
PVT_roofs_top_m2 |
Collector surface area on roof tops. |
PVT_roofs_top_Q_kWh |
Heat production from photovoltaic-thermal panels on roof tops |
PVT_walls_east_E_kWh |
Electricity production from photovoltaic-thermal panels on east facades |
PVT_walls_east_m2 |
Collector surface area on east facades. |
PVT_walls_east_Q_kWh |
Heat production from photovoltaic-thermal panels on east facades |
PVT_walls_north_E_kWh |
Electricity production from photovoltaic-thermal panels on north facades |
PVT_walls_north_m2 |
Collector surface area on north facades. |
PVT_walls_north_Q_kWh |
Heat production from photovoltaic-thermal panels on north facades |
PVT_walls_south_E_kWh |
Electricity production from photovoltaic-thermal panels on south facades |
PVT_walls_south_m2 |
Collector surface area on south facades. |
PVT_walls_south_Q_kWh |
Heat production from photovoltaic-thermal panels on south facades |
PVT_walls_west_E_kWh |
Electricity production from photovoltaic-thermal panels on west facades |
PVT_walls_west_m2 |
West facing wall collector surface area. |
PVT_walls_west_Q_kWh |
Heat production from photovoltaic-thermal panels on west facades |
Q_PVT_gen_kWh |
Total heat generated by the collector. |
Q_PVT_l_kWh |
Collector heat loss. |
radiation_kWh |
Total radiatiative potential. |
T_PVT_re_C |
Collector heating supply temperature. |
T_PVT_sup_C |
Collector heating supply temperature. |
SC_metadata_results¶
path: outputs/data/potentials/solar/B001_SC_ET_sensors.csv
The following file is used by these scripts:
Variable | Description |
---|---|
area_installed_module_m2 |
The area of the building suface covered by one solar panel |
AREA_m2 |
Surface area. |
array_spacing_m |
Spacing between solar arrays. |
B_deg |
Tilt angle of the installed solar panels |
BUILDING |
Unique building ID. It must start with a letter. |
CATB |
Category according to the tilt angle of the panel |
CATGB |
Category according to the annual radiation on the panel surface |
CATteta_z |
Category according to the surface azimuth of the panel |
intersection |
flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) |
orientation |
Orientation of the surface (north/east/south/west/top) |
SURFACE |
Unique surface ID for each building exterior surface. |
surface |
Unique surface ID for each building exterior surface. |
surface_azimuth_deg |
Azimuth angle of the panel surface e.g. south facing = 180 deg |
tilt_deg |
Tilt angle of roof or walls |
total_rad_Whm2 |
Total radiatiative potential of a given surfaces area. |
TYPE |
Surface typology. |
type_orientation |
Concatenated surface type and orientation. |
Xcoor |
Describes the position of the x vector. |
Xdir |
Directional scalar of the x vector. |
Ycoor |
Describes the position of the y vector. |
Ydir |
Directional scalar of the y vector. |
Zcoor |
Describes the position of the z vector. |
Zdir |
Directional scalar of the z vector. |
SC_results¶
path: outputs/data/potentials/solar/B001_SC_ET.csv
The following file is used by these scripts: decentralized
Variable | Description |
---|---|
Area_SC_m2 |
Total area of investigated collector. |
Date |
Date and time in hourly steps. |
Eaux_SC_kWh |
Auxiliary electricity consumed by the collector. |
mcp_SC_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
Q_SC_gen_kWh |
Total heat generated by the collector. |
Q_SC_l_kWh |
Collector heat loss. |
radiation_kWh |
Total radiatiative potential. |
SC_ET_roofs_top_m2 |
Collector surface area on roof tops. |
SC_ET_roofs_top_Q_kWh |
Heat production from solar collectors on roof tops |
SC_ET_walls_east_m2 |
Collector surface area on east facades. |
SC_ET_walls_east_Q_kWh |
Heat production from solar collectors on east facades |
SC_ET_walls_north_m2 |
Collector surface area on north facades. |
SC_ET_walls_north_Q_kWh |
Heat production from solar collectors on north facades |
SC_ET_walls_south_m2 |
Collector surface area on south facades. |
SC_ET_walls_south_Q_kWh |
Heat production from solar collectors on south facades |
SC_ET_walls_west_m2 |
Collector surface area on west facades. |
SC_ET_walls_west_Q_kWh |
Heat production from solar collectors on west facades |
T_SC_re_C |
Collector hot water return temperature. |
T_SC_sup_C |
Collector hot water supply temperature. |
SC_total_buildings¶
path: outputs/data/potentials/solar/SC_ET_total_buildings.csv
The following file is used by these scripts:
Variable | Description |
---|---|
Area_SC_m2 |
Total area of investigated collector. |
Eaux_SC_kWh |
Auxiliary electricity consumed by the collector. |
Name |
Unique building ID. |
Q_SC_gen_kWh |
Total heat generated by the collector. |
Q_SC_l_kWh |
Collector heat loss. |
radiation_kWh |
Total radiatiative potential. |
SC_ET_roofs_top_m2 |
Roof top collector surface area. |
SC_ET_roofs_top_Q_kWh |
Heat production from solar collectors on roof tops |
SC_ET_walls_east_m2 |
East facing wall collector surface area. |
SC_ET_walls_east_Q_kWh |
Heat production from solar collectors on east facades |
SC_ET_walls_north_m2 |
North facing wall collector surface area. |
SC_ET_walls_north_Q_kWh |
Heat production from solar collectors on west facades |
SC_ET_walls_south_m2 |
South facing wall collector surface area. |
SC_ET_walls_south_Q_kWh |
Heat production from solar collectors on south facades |
SC_ET_walls_west_m2 |
West facing wall collector surface area. |
SC_ET_walls_west_Q_kWh |
Heat production from solar collectors on west facades |
SC_totals¶
path: outputs/data/potentials/solar/SC_FP_total.csv
The following file is used by these scripts: optimization
Variable | Description |
---|---|
Area_SC_m2 |
Collector surface area on south facades. |
Date |
Date and time in hourly steps. |
Eaux_SC_kWh |
Auxiliary electricity consumed by the collector. |
mcp_SC_kWperC |
Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. |
Q_SC_gen_kWh |
Total heat generated by the collector. |
Q_SC_l_kWh |
Collector heat loss. |
radiation_kWh |
Total radiatiative potential. |
SC_FP_roofs_top_m2 |
Collector surface area on roof tops. |
SC_FP_roofs_top_Q_kWh |
Heat production from solar collectors on roof tops |
SC_FP_walls_east_m2 |
Collector surface area on east facades. |
SC_FP_walls_east_Q_kWh |
Heat production from solar collectors on east facades |
SC_FP_walls_north_m2 |
Collector surface area on north facades. |
SC_FP_walls_north_Q_kWh |
Heat production from solar collectors on north facades |
SC_FP_walls_south_m2 |
Collector surface area on south facades. |
SC_FP_walls_south_Q_kWh |
Heat production from solar collectors on south facades |
SC_FP_walls_west_m2 |
Collector surface area on west facades. |
SC_FP_walls_west_Q_kWh |
Heat production from solar collectors on west facades |
T_SC_re_C |
Collector hot water return temperature. |
T_SC_sup_C |
Collector hot water supply temperature. |