Architecture
The architecture of the CEA is still a bit in flux, but some main components have already been developed and will be explained in this chapter. The following figure shows a high-level view of the main components of the CEA:
digraph cea_objects { node [shape=box, fontname="Helvetica"]; demand [label="Demand calculation", style="filled"]; sensitivity [label="Sensitivity Analysis"]; calibration [label="Transient Bayesian Calibration"]; optimization [label="Network Optimization"]; analysis [label="Mobility / Life Cycle Analysis"]; plots [label="Data Visualization"]; { node [style="dashed"]; rank=same; bpr [label="bpr (BuildingPropertiesRow)"]; tsd [label="tsd (timestep data)"]; locator [label="locator (InputLocator)", style="filled"]; } db [label="db (Archetypes)", shape="folder"]; scenario [label="Case Study (scenario)", shape="folder"]; locator -> bpr; locator -> scenario [label=" read / write"]; locator -> db [label=" write"]; {rank=same; demand; analysis; plots; } {rank=same; db; scenario; } demand -> locator; demand -> tsd; demand -> bpr; analysis -> locator; plots -> locator; sensitivity -> demand; calibration -> demand; optimization -> demand; db -> scenario [label=" preprocessing "]; }
Demand calculation
At the core of the CEA is the demand calculation. The demand calculation retrieves inputs from the scenario folder and stores outputs back to the scenario folder. A preprocessing step can be used to add archetype data to a scenario as a first guess of certain parameters.
The demand calculation uses a special variable called tsd
to store
information about the timestep data during the calculation of thermal
loads for each building. The data structure used is a simple python
dictionary of NumPy arrays. Each of these arrays has the length 8760, to
total number of hours of the year. The keys of the tsd
dictionary
are the names of the state variables of the simulation.
The demand calculation also uses a variable bpr
to store building
properties of a single building.
InputLocator
The cea.inputlocator.InputLocator
class encapsulates the code for
creating paths for input and output to the archetypes and the contents
of the scenario (input and output files). An instance of this class is
found in most of the code and is always named locator
, unless
multiple InputLocator
objects are used, e.g. for comparing
scenarios.
Each method of the locator
starts with get_*
and returns a
string containing the full path to the resource requested. These
get_*
methods should be the only way to obtain file- and folder
names in the CEA - files and folders should especially not be
concatenated with strings and backslashes (\
). Instead, new paths
should be introduced as methods of the InputLocator
class.
One of the main benefits of doing this is that it makes documentation of
what files are read / written by what module of the CEA easier. The
funcionlogger
module can be used to trace these calls for generating
documentation.
The private method _ensure_folder(*paths)
is used to join path
components and at the same time ensure that the folders are present in
the scenario folder, creating them with os.makedirs
if necessary.
NOTE: The list of get_*
methods is getting very long. We might
end up creating a namespace hierarchy for grouping related paths
together.
Analysis and Visualization
Separate modules exist for analyzing different aspects of a scenario.
Some of the analysis modules operate only on the input data (LCA for
embedded emissions, mobility) and others operate on the output of the
demand module (LCA for emissions due to operation). These modules are
grouped in the folder cea/analysis
.
The folder cea/plots
contains modules for plotting outputs of the
calculations.
“Higher order” modules